Author: Neyman, Greg; Irvin, Charlene Babcock
Title: A Single Ventilator for Multiple Simulated Patients to Meet Disaster Surge Cord-id: tqhexzdp Document date: 2008_6_28
ID: tqhexzdp
Snippet: Objectives To determine if a ventilator available in an emergency department could quickly be modified to provide ventilation for four adults simultaneously. Methods Using lung simulators, readily available plastic tubing, and ventilators (840 Series Ventilator; Puritanâ€Bennett), human lung simulators were added in parallel until the ventilator was ventilating the equivalent of four adults. Data collected included peak pressure, positive endâ€expiratory pressure, total tidal volume, and total
Document: Objectives To determine if a ventilator available in an emergency department could quickly be modified to provide ventilation for four adults simultaneously. Methods Using lung simulators, readily available plastic tubing, and ventilators (840 Series Ventilator; Puritanâ€Bennett), human lung simulators were added in parallel until the ventilator was ventilating the equivalent of four adults. Data collected included peak pressure, positive endâ€expiratory pressure, total tidal volume, and total minute ventilation. Any obvious asymmetry in the delivery of gas to the lung simulators was also documented. The ventilator was run for almost 12 consecutive hours (5.5 hours of pressure control and more than six hours of volume control). Results Using readily available plastic tubing set up to minimize dead space volume, the four lung simulators were easily ventilated for 12 hours using one ventilator. In pressure control (set at 25 mm H(2)O), the mean tidal volume was 1,884 mL (approximately 471 mL/lung simulator) with an average minute ventilation of 30.2 L/min (or 7.5 L/min/lung simulator). In volume control (set at 2 L), the mean peak pressure was 28 cm H(2)O and the minute ventilation was 32.5 L/min total (8.1 L/min/lung simulator). Conclusions A single ventilator may be quickly modified to ventilate four simulated adults for a limited time. The volumes delivered in this simulation should be able to sustain four 70â€kg individuals. While further study is necessary, this pilot study suggests significant potential for the expanded use of a single ventilator during cases of disaster surge involving multiple casualties with respiratory failure.
Search related documents:
Co phrase search for related documents- additional support and long period: 1
- additional support and lung injury: 1
- additional support and lung simulator: 1
- adequate oxygenation and lung injury: 1, 2, 3, 4, 5, 6, 7, 8
- adequate oxygenation and lung model: 1, 2, 3
- long period and lung injury: 1
Co phrase search for related documents, hyperlinks ordered by date