Author: Mueller, Thomas; Kompatscher, Julia; La Guardia, Mario
Title: Diagnostic performance of the Elecsys SARSâ€CoVâ€2 antigen assay in the clinical routine of a tertiary care hospital: Preliminary results from a singleâ€center evaluation Cord-id: trf131vo Document date: 2021_7_12
ID: trf131vo
Snippet: BACKGROUND: This report describes a manufacturerâ€independent evaluation of the diagnostic accuracy of the Elecsys SARSâ€CoVâ€2 antigen assay from Roche Diagnostics in a tertiary care setting. METHODS: In this singleâ€center study, we used nasopharyngeal swabs from 403 cases from the emergency department and intensive care unit of our hospital. The reference standard for detecting SARSâ€CoVâ€2 was the reverseâ€transcription polymerase chain reaction (RTâ€PCR) assay. Cycle threshold (Ct)
Document: BACKGROUND: This report describes a manufacturerâ€independent evaluation of the diagnostic accuracy of the Elecsys SARSâ€CoVâ€2 antigen assay from Roche Diagnostics in a tertiary care setting. METHODS: In this singleâ€center study, we used nasopharyngeal swabs from 403 cases from the emergency department and intensive care unit of our hospital. The reference standard for detecting SARSâ€CoVâ€2 was the reverseâ€transcription polymerase chain reaction (RTâ€PCR) assay. Cycle threshold (Ct) values were recorded for positive RTâ€PCR assays. The index test was the Elecsys SARSâ€CoVâ€2 antigen assay. This electrochemiluminescence immunoassay produces results as cutoff index (COI) values, with values ≥1.00 being reported as positive. RESULTS: Of the 403 cases, 47 showed positive results in RTâ€PCR assays. Of the 47 RTâ€PCRâ€positive cases, 12 showed positive results in the antigen assay. Of the 356 RTâ€PCRâ€negative cases, all showed negative results in the antigen assay. Thus, the antigen assay showed a sensitivity of 26% (95% CI, 14%â€40%) and specificity of 100% (95% CI, 99%â€100%). Analysis of the relationship between Ct values and COI values in the 47 RTâ€PCRâ€positive cases showed a correlation coefficient of −0.704 (95% CI, −0.824 to −0.522). The trueâ€positive rate of the antigen assay for Ct values of 15–24.9, 25–29.9, 30–34.9, and 35–39.9 was 100%, 44%, 8%, and 6%, respectively. CONCLUSIONS: The Elecsys SARSâ€CoVâ€2 antigen assay has a low sensitivity for detecting SARSâ€CoVâ€2 from nasopharyngeal swabs. Hence, we decided to not use this assay in the clinical routine of our hospital.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date