Author: Zhang, Yang; Dai, Chunyang; Wang, Huiyan; Gao, Yong; Li, Tuantuan; Fang, Yan; Shen, Zuojun; Chen, Lichang; Chen, Zhaowu; Ma, Xuejun; Li, Ming
Title: Analysis and validation of a highly sensitive one-step nested quantitative real-time polymerase chain reaction assay for specific detection of severe acute respiratory syndrome coronavirus 2 Cord-id: h960dpxn Document date: 2020_12_28
ID: h960dpxn
Snippet: BACKGROUND: Coronavirus disease 2019 (COVID-19), caused by SARS-CoV-2, is posing a serious threat to global public health. Reverse transcriptase real-time quantitative polymerase chain reaction (qRT-PCR) is widely used as the gold standard for clinical detection of SARS-CoV-2. Due to technical limitations, the reported positive rates of qRT-PCR assay of throat swab samples vary from 30 to 60%. Therefore, the evaluation of alternative strategies to overcome the limitations of qRT-PCR is required.
Document: BACKGROUND: Coronavirus disease 2019 (COVID-19), caused by SARS-CoV-2, is posing a serious threat to global public health. Reverse transcriptase real-time quantitative polymerase chain reaction (qRT-PCR) is widely used as the gold standard for clinical detection of SARS-CoV-2. Due to technical limitations, the reported positive rates of qRT-PCR assay of throat swab samples vary from 30 to 60%. Therefore, the evaluation of alternative strategies to overcome the limitations of qRT-PCR is required. A previous study reported that one-step nested (OSN)-qRT-PCR revealed better suitability for detecting SARS-CoV-2. However, information on the analytical performance of OSN-qRT-PCR is insufficient. METHOD: In this study, we aimed to analyze OSN-qRT-PCR by comparing it with droplet digital PCR (ddPCR) and qRT-PCR by using a dilution series of SARS-CoV-2 pseudoviral RNA and a quality assessment panel. The clinical performance of OSN-qRT-PCR was also validated and compared with ddPCR and qRT-PCR using specimens from COVID-19 patients. RESULT: The limit of detection (copies/ml) of qRT-PCR, ddPCR, and OSN-qRT-PCR were 520.1 (95% CI: 363.23–1145.69) for ORF1ab and 528.1 (95% CI: 347.7–1248.7) for N, 401.8 (95% CI: 284.8–938.3) for ORF1ab and 336.8 (95% CI: 244.6–792.5) for N, and 194.74 (95% CI: 139.7–430.9) for ORF1ab and 189.1 (95% CI: 130.9–433.9) for N, respectively. Of the 34 clinical samples from COVID-19 patients, the positive rates of OSN-qRT-PCR, ddPCR, and qRT-PCR were 82.35% (28/34), 67.65% (23/34), and 58.82% (20/34), respectively. CONCLUSION: In conclusion, the highly sensitive and specific OSN-qRT-PCR assay is superior to ddPCR and qRT-PCR assays, showing great potential as a technique for detection of SARS-CoV-2 in patients with low viral loads.
Search related documents:
Co phrase search for related documents- accuracy sensitivity and acid extraction: 1, 2
- accuracy sensitivity and acute phase: 1, 2, 3
- accuracy sensitivity and load sample: 1
- accuracy sensitivity and lod probit analysis: 1
- accuracy sensitivity and low concentration: 1, 2, 3
- accuracy sensitivity and low respiratory: 1
- accurate sensitive and acid detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
- accurate sensitive and acid extraction: 1, 2
- accurate sensitive and acid extraction method: 1
- accurate sensitive and locked nucleic acid: 1
- accurate sensitive and lod probit analysis: 1
- accurate sensitive and low concentration: 1
- acid detection and acute phase: 1, 2, 3
- acid detection and load sample: 1
- acid detection and locked nucleic acid: 1
- acid detection and low concentration: 1, 2
- acid detection and low respiratory: 1, 2, 3, 4, 5
- acid extraction and low concentration: 1, 2, 3
- acid extraction method and low concentration: 1, 2
Co phrase search for related documents, hyperlinks ordered by date