Author: Huang, Yafeng; Zhang, Lulu; Zhang, Hao; Li, Yichen; Liu, Luyao; Chen, Yuanyuan; Qiu, Xianbo; Yu, Duli
                    Title: Development of a Portable SPR Sensor for Nucleic Acid Detection  Cord-id: v38xdxr1  Document date: 2020_5_21
                    ID: v38xdxr1
                    
                    Snippet: Nucleic acid detection is of great significance in clinical diagnosis, environmental monitoring and food safety. Compared with the traditional nucleic acid amplification detection method, surface plasmon resonance (SPR) sensing technology has the advantages of being label-free, having simple operation, and providing real-time detection. However, the angle scanning system in many SPR angle modulation detection applications usually requires a high-resolution stepper motor and complex mechanical st
                    
                    
                    
                     
                    
                    
                    
                    
                        
                            
                                Document: Nucleic acid detection is of great significance in clinical diagnosis, environmental monitoring and food safety. Compared with the traditional nucleic acid amplification detection method, surface plasmon resonance (SPR) sensing technology has the advantages of being label-free, having simple operation, and providing real-time detection. However, the angle scanning system in many SPR angle modulation detection applications usually requires a high-resolution stepper motor and complex mechanical structure to adjust the angle. In this paper, a portable multi-angle scanning SPR sensor was designed. The sensor only uses one stepping motor to rotate a belt, and the belt pulls the mechanical linkages of incident light and reflected light to move in opposite directions for achieving the SPR angle scanning mode that keeps the incident angle and reflected angle equal. The sensor has an angle scanning accuracy of 0.002°, response sensitivity of 3.72 × 10(−6) RIU (refractive index unit), and an angle scanning range of 30°–74°. The overall size of the system is only 480 mm × 150 mm × 180 mm. The portable SPR sensor was used to detect nucleic acid hybridization on a gold film chip modified with bovine serum albumin (BSA). The result revealed that the sensor had high sensitivity and fast response, and could successfully accomplish the hybridization detection of target DNA solution of 0.01 μmol/mL.
 
  Search related documents: 
                                Co phrase  search for related documents- absolute quantification and acid detection: 1, 2, 3, 4, 5, 6
- absolute quantification and low detection: 1
- accuracy scan and acid detection: 1, 2
- acid detection and low detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37
- acid detection and low detection limit: 1, 2, 3, 4
- acid detection and low surface: 1
- acid detection and magnetic bead: 1, 2, 3, 4
- acid interaction and low detection: 1
- acid sensing and low detection: 1, 2
- acid sensing and low detection limit: 1
 
                                Co phrase  search for related documents, hyperlinks ordered by date