Selected article for: "pneumonia diagnosis and SARS detection"

Author: Zhang, Chunyan; Zhou, Lei; Du, Kang; Zhang, Ying; Wang, Jing; Chen, Lijuan; Lyu, Yanning; Li, Jun; Liu, Hao; Huo, Junli; Li, Fei; Wang, Jiayi; Sang, Peipei; Lin, Si; Xiao, Yi; Zhang, Kan; He, Kunlun
Title: Foundation and Clinical Evaluation of a New Method for Detecting SARS-CoV-2 Antigen by Fluorescent Microsphere Immunochromatography
  • Cord-id: hg921c2y
  • Document date: 2020_11_30
  • ID: hg921c2y
    Snippet: PURPOSE: To develop a rapid detection reagent for SARS-CoV-2 antigen for the auxiliary diagnosis of new coronary pneumonia (COVID-19), and perform the methodological evaluation and clinical evaluation of the reagent. METHOD: SARS-CoV-2 N-protein test strip was created by combining fluorescent microsphere labeling technology and immunochromatographic technology, based on the principle of double antibody sandwich. Then we evaluated the analytical capability and clinical application of the strips.
    Document: PURPOSE: To develop a rapid detection reagent for SARS-CoV-2 antigen for the auxiliary diagnosis of new coronary pneumonia (COVID-19), and perform the methodological evaluation and clinical evaluation of the reagent. METHOD: SARS-CoV-2 N-protein test strip was created by combining fluorescent microsphere labeling technology and immunochromatographic technology, based on the principle of double antibody sandwich. Then we evaluated the analytical capability and clinical application of the strips. RESULT: The limit of detection of the strips for recombinant N protein was 100 ng/ml and for activated SARS -CoV-2 virus was 1 × 10(3) TCID(50)/ml. The strips also have high analytical specificity and anti-interference capability. According to the predetermined cut-off value, the specificity of the test strip in healthy controls and patients with other respiratory disease was 100.00 and 97.29%, the sensitivity in COVID-19 cases at progress stage and cured stage was 67.15 and 7.02%. The positive percentage agreement and negative percentage agreement of antigen strip to RNA test were 83.16 and 94.45%. CONCLUSION: SARS-CoV-2 fluorescence immunochromatographic test strip can achieve fast, sensitive and accurate detection, which can meet the clinical requirements for rapid detection of viruses on the spot.

    Search related documents:
    Co phrase search for related documents
    • accuracy efficiency and logistic regression model: 1
    • accuracy efficiency improve and acid detection: 1
    • accuracy sensitivity and acid detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17
    • accuracy sensitivity and acid extraction: 1, 2
    • accuracy sensitivity and acid testing: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • accuracy sensitivity and logistic regression model: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19
    • acid detection and activate virus: 1
    • acid detection and live virus: 1, 2, 3, 4
    • acid detection and live virus detect: 1
    • acid detection and logistic regression model: 1, 2, 3, 4
    • acid extraction and live virus: 1, 2
    • acid testing and live virus: 1
    • activate virus and live virus: 1