Selected article for: "approach safety efficacy and safety efficacy"

Author: Dreher, Michael; Cornelissen, Christian Gabriel; Reddemann, Manuel Armin; Müller, Annegret; Hübel, Christian; Müller, Tobias
Title: Nebulized versus Standard Local Application of Lidocaine during Flexible Bronchoscopy: A Randomized Controlled Trial.
  • Cord-id: iqr09567
  • Document date: 2016_1_1
  • ID: iqr09567
    Snippet: BACKGROUND Endobronchial administration of local anesthetics such as lidocaine is often used for cough suppression during bronchoscopy. To achieve a better distribution of lidocaine in the tracheobronchial tree, spray catheters have been developed, allowing nebulization of the local anesthetic solution. However, there are little data on the efficacy and safety of this approach, or on the consumption of sedative drugs and lidocaine during nebulized administration. OBJECTIVES To investigate the to
    Document: BACKGROUND Endobronchial administration of local anesthetics such as lidocaine is often used for cough suppression during bronchoscopy. To achieve a better distribution of lidocaine in the tracheobronchial tree, spray catheters have been developed, allowing nebulization of the local anesthetic solution. However, there are little data on the efficacy and safety of this approach, or on the consumption of sedative drugs and lidocaine during nebulized administration. OBJECTIVES To investigate the tolerability of nebulized lidocaine compared to conventional lidocaine administration via syringe through the working channel of the bronchoscope in patients undergoing bronchoscopy. Consumption of sedative drugs and lidocaine was also compared between the two lidocaine administration approaches. METHODS Patients requiring bronchoscopy with endobronchial or transbronchial biopsy were randomly assigned to receive topical lidocaine either via syringe or via nebulizer. Endpoints were consumption of lidocaine and sedative drugs, as well as patient tolerance and safety. RESULTS Thirty patients were included, 15 in each group. Patients in the nebulizer group required lower doses of endobronchial lidocaine (184.7 ± 67.98 vs. 250.7 ± 21.65 mg, p = 0.0045) and intravenous fentanyl (0.033 ± 0.041 vs. 0.067 ± 0.045 mg, p = 0.0236) than those in the syringe group; midazolam or propofol dosages did not differ between the two groups. In addition, there were no between-group differences in patient tolerance or safety (all p > 0.05). CONCLUSION Endobronchial administration of lidocaine during bronchoscopy via nebulizer was found to be well tolerated and safe and was associated with reduced lidocaine and fentanyl dosages compared to administration via syringe.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1