Author: Jacoby, Sidney M; Bachoura, Abdo; Chen, Neal C; Shin, Eon K; Katolik, Leonid I
Title: One-stage Integra coverage for fingertip injuries. Cord-id: f8xex3o5 Document date: 2013_1_1
ID: f8xex3o5
Snippet: BACKGROUND We hypothesize that one-stage Integra skin coverage is an effective treatment modality for the treatment of fingertip defects. METHODS Nine patients who sustained fingertip injuries were treated with one-stage Integra coverage. In all cases, Integra was placed directly on bone. Static two-point discrimination and the Semmes-Weinstein Monofilament Test (SWMFT) were used to determine the sensations of the affected and opposite unaffected digit. The QuickDASH, Cold Intolerance Symptom Se
Document: BACKGROUND We hypothesize that one-stage Integra skin coverage is an effective treatment modality for the treatment of fingertip defects. METHODS Nine patients who sustained fingertip injuries were treated with one-stage Integra coverage. In all cases, Integra was placed directly on bone. Static two-point discrimination and the Semmes-Weinstein Monofilament Test (SWMFT) were used to determine the sensations of the affected and opposite unaffected digit. The QuickDASH, Cold Intolerance Symptom Severity (CISS), visual analog scale (VAS), and a 0-10-point pain scale were administered to assess patient function, satisfaction, and pain levels. RESULTS The mean age was 53.1 years (39-61). There were 8 males and 1 female. The average area covered was 2.3 cm(2) (1.0-3.2). The mean follow-up duration was 16 months (8-46). The median QuickDASH, CISS score, VAS patient satisfaction, and 0-10 pain score were 9.1 (2.3-40.9), 18 (4-30), 10 (most satisfied) (7-10), and 0 (0-3), respectively. Five patients were evaluated for their digital sensory perception. The mean static two-point discrimination was 9.6 mm for the affected digit and 4.6 mm for the opposite unaffected digit. The median SWMFT was 4.31 for the affected digit and 3.61 for the opposite unaffected digit. CONCLUSION For small soft tissue and bone defects involving the fingertip, the use of Integra without further skin grafting appears to be effective, avoids the morbidity of the donor site, and avoids a second surgery. Despite mild sensory deficits, patients were satisfied with the results and fully functional during short-term follow-up.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date