Selected article for: "arterial blood gas ABG analysis and blood gas"

Author: Thijssen, Mark; Janssen, Loes; le Noble, Jos; Foudraine, Norbert
Title: Facing SpO(2) and SaO(2) discrepancies in ICU patients: is the perfusion index helpful?
  • Cord-id: 9bdqxf59
  • Document date: 2019_8_7
  • ID: 9bdqxf59
    Snippet: Peripheral oxygen saturation (SpO(2)) measured by pulse oximetry is an unreliable surrogate marker for arterial oxygenation (SaO(2)) in critically ill patients. We hypothesized that a higher perfusion index (PFI) would be associated with better accuracy of SpO(2) measurement. We retrospectively collected SaO(2), SpO(2), and PFI data for each arterial blood gas (ABG) analysis in a cohort of intensive care unit patients. PFI was categorised as low (PFI < 1.0), intermediate (1.0 ≤ PFI ≤ 2.5), o
    Document: Peripheral oxygen saturation (SpO(2)) measured by pulse oximetry is an unreliable surrogate marker for arterial oxygenation (SaO(2)) in critically ill patients. We hypothesized that a higher perfusion index (PFI) would be associated with better accuracy of SpO(2) measurement. We retrospectively collected SaO(2), SpO(2), and PFI data for each arterial blood gas (ABG) analysis in a cohort of intensive care unit patients. PFI was categorised as low (PFI < 1.0), intermediate (1.0 ≤ PFI ≤ 2.5), or high (PFI > 2.5). The correlation between SpO(2) and SaO(2) was studied using Pearson’s correlation. The Bland–Altman plot was used to analyse the agreement between SpO(2) and SaO(2). Furthermore, the correlation between the (SpO(2)–SaO(2)) difference and PFI was assessed. The level of (dis)agreement was calculated for the three PFI categories separately. Overall, 281 patients and 1281 data points were analysed. There was a significant correlation between SaO(2) and SpO(2) (r = 0.69, p < 0.01). The Bland–Altman analysis revealed a mean difference between SaO(2) and SpO(2) of 0.2% with limits of agreement of ± 6% (SD ± 2%). The correlation between the PFI and the (SpO(2)–SaO(2)) difference was low; the (SpO(2)–SaO(2)) difference improved only marginally with higher PFI values. The accuracy of pulse oximetry for estimating arterial oxygenation was moderate and improved little with increasing PFI values. Thus, the additive value of PFI in clinical decision making is limited. Therefore, we advise performing an ABG before adjusting fraction of inspired oxygen (FiO(2)) settings.

    Search related documents:
    Co phrase search for related documents
    • abg measurement and acid base disturbance: 1
    • acid base disturbance and admission diagnosis: 1