Selected article for: "additional testing and low sensitive"

Author: Menchinelli, Giulia; Bordi, Licia; Liotti, Flora Marzia; Palucci, Ivana; Capobianchi, Maria Rosaria; Sberna, Giuseppe; Lalle, Eleonora; Romano, Lucio; De Angelis, Giulia; Marchetti, Simona; Sanguinetti, Maurizio; Cattani, Paola; Posteraro, Brunella
Title: Lumipulse G SARS-CoV-2 Ag assay evaluation using clinical samples from different testing groups.
  • Cord-id: grsmmjxh
  • Document date: 2021_4_7
  • ID: grsmmjxh
    Snippet: OBJECTIVES Compared to RT-PCR, lower performance of antigen detection assays, including the Lumipulse G SARS-CoV-2 Ag assay, may depend on specific testing scenarios. METHODS We tested 594 nasopharyngeal swab samples from individuals with COVID-19 (RT-PCR cycle threshold [Ct] values ≤ 40) or non-COVID-19 (Ct values > 40) diagnoses. RT-PCR positive samples were assigned to diagnostic, screening, or monitoring groups of testing. RESULTS With a limit of detection of 1.2 × 104 SARS-CoV-2 RNA copi
    Document: OBJECTIVES Compared to RT-PCR, lower performance of antigen detection assays, including the Lumipulse G SARS-CoV-2 Ag assay, may depend on specific testing scenarios. METHODS We tested 594 nasopharyngeal swab samples from individuals with COVID-19 (RT-PCR cycle threshold [Ct] values ≤ 40) or non-COVID-19 (Ct values > 40) diagnoses. RT-PCR positive samples were assigned to diagnostic, screening, or monitoring groups of testing. RESULTS With a limit of detection of 1.2 × 104 SARS-CoV-2 RNA copies/ml, Lumipulse showed positive percent agreement (PPA) of 79.9% (155/194) and negative percent agreement of 99.3% (397/400), whereas PPAs were 100% for samples with Ct values of <18 or 18-<25 and 92.5% for samples with Ct values of 25-<30. By three groups, Lumipulse showed PPA of 87.0% (60/69), 81.1% (43/53), or 72.2% (52/72), respectively, whereas PPA was 100% for samples with Ct values of <18 or 18-<25, and was 94.4, 80.0, or 100% for samples with Ct values of 25-<30, respectively. Additional testing of RT-PCR positive samples for SARS-CoV-2 subgenomic RNA showed that, by three groups, PPA was 63.8% (44/69), 62.3% (33/53), or 33.3% (24/72), respectively. PPAs dropped to 55.6, 20.0, or 41.7% for samples with Ct values of 25-<30, respectively. All 101 samples with a subgenomic RNA positive result had a Lumipulse assay's antigen positive result, whereas only 54 (58.1%) of remaining 93 samples had a Lumipulse assay's antigen positive result. CONCLUSIONS Lumipulse assay was highly sensitive in samples with low RT-PCR Ct values, implying repeated testing to reduce consequences of false-negative results.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1