Selected article for: "air temperature and humidity temperature"

Author: Luo, Hao; Zhong, Lexuan
Title: Ultraviolet germicidal irradiation (UVGI) for in-duct airborne bioaerosol disinfection: Review and analysis of design factors
  • Cord-id: ih5b32i4
  • Document date: 2021_6_15
  • ID: ih5b32i4
    Snippet: The rapid increase in global cases of COVID-19 illness and death requires the implementation of appropriate and efficient engineering controls to improve indoor air quality. This paper focuses on the use of the ultraviolet germicidal irradiation (UVGI) air purification technology in HVAC ducts, which is particularly applicable to buildings where fully shutting down air recirculation is not feasible. Given the poor understanding of the in-duct UVGI system regarding its working mechanisms, designs
    Document: The rapid increase in global cases of COVID-19 illness and death requires the implementation of appropriate and efficient engineering controls to improve indoor air quality. This paper focuses on the use of the ultraviolet germicidal irradiation (UVGI) air purification technology in HVAC ducts, which is particularly applicable to buildings where fully shutting down air recirculation is not feasible. Given the poor understanding of the in-duct UVGI system regarding its working mechanisms, designs, and applications, this review has the following key research objectives: • Identifying the critical parameters for designing a UVGI system, including the characterization of lamp output, behavior of the target microbial UV dose-response, and evaluation of the inactivation performance and energy consumption. • Elucidating the effects of environmental factors (air velocity, air temperature, and humidity) on the UVGI system design parameters and optimization of the in-duct UVGI design. • Summarizing existing UVGI system designs in the literature and illustrating their germicidal and energy performance in light of COVID-19 mitigation.

    Search related documents:
    Co phrase search for related documents
    • acute respiratory syndrome and long term effect: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • acute respiratory syndrome and los angeles: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24
    • acute respiratory syndrome and low air temperature: 1, 2
    • acute respiratory syndrome and low outdoor temperature: 1
    • acute respiratory syndrome and low pressure: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46
    • acute respiratory syndrome and low pressure mercury: 1, 2
    • acute respiratory syndrome and low pressure mercury lamp: 1
    • acute respiratory syndrome and low standard deviation: 1