Selected article for: "probe primer and SARS detection"

Author: Mögling, Ramona; Meijer, Adam; Berginc, Natasa; Bruisten, Sylvia; Charrel, Remi; Coutard, Bruno; Eckerle, Isabella; Enouf, Vincent; Hungnes, Olav; Korukluoglu, Gülay; Kossyvakis, Thanos; Mentis, Andreas; Molenkamp, Richard; Muradrasoli, Shaman; Papa, Anna; Pigny, Fiona; Thirion, Laurence; van der Werf, Sylvie; Reusken, Chantal
Title: Delayed Laboratory Response to COVID-19 Caused by Molecular Diagnostic Contamination
  • Cord-id: z1jr2urk
  • Document date: 2020_8_25
  • ID: z1jr2urk
    Snippet: The emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) created an exceptional situation in which numerous laboratories in Europe simultaneously implemented SARS-CoV-2 diagnostics. These laboratories reported in February 2020 that commercial primer and probe batches for SARS-CoV-2 detection were contaminated with synthetic control material, causing delays of regional testing roll-out in various countries.
    Document: The emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) created an exceptional situation in which numerous laboratories in Europe simultaneously implemented SARS-CoV-2 diagnostics. These laboratories reported in February 2020 that commercial primer and probe batches for SARS-CoV-2 detection were contaminated with synthetic control material, causing delays of regional testing roll-out in various countries.

    Search related documents:
    Co phrase search for related documents
    • acute respiratory syndrome coronavirus and additional laboratory: 1, 2, 3, 4, 5
    • acute respiratory syndrome coronavirus and long nucleic acid: 1
    • acute respiratory syndrome coronavirus and long oligonucleotide: 1