Author: Faulds, Eileen R; Boutsicaris, Andrew; Sumner, Lyndsey; Jones, Laureen; McNett, Molly; Smetana, Keaton S; May, Casey C; Buschur, Elizabeth; Exline, Mathew C; Ringel, Mathew D; Dungan, Kathleen
Title: Use of Continuous Glucose Monitor in Critically Ill COVID-19 Patients Requiring Insulin Infusion: An Observational Study. Cord-id: o7kc39f2 Document date: 2021_6_8
ID: o7kc39f2
Snippet: CONTEXT The coronavirus disease 2019 (COVID-19) pandemic has created a need for remote blood glucose (BG) monitoring in the intensive care unit (ICU). OBJECTIVE To evaluate feasibility and patient safety of a hybrid monitoring strategy of point of care (POC) BG plus continuous glucose monitor (CGM) in the ICU. DESIGN Retrospective analysis. SETTING ICU of an academic medical center. PATIENTS Patients with COVID-19 on intravenous (IV) insulin. INTERVENTION After meeting initial validation criteri
Document: CONTEXT The coronavirus disease 2019 (COVID-19) pandemic has created a need for remote blood glucose (BG) monitoring in the intensive care unit (ICU). OBJECTIVE To evaluate feasibility and patient safety of a hybrid monitoring strategy of point of care (POC) BG plus continuous glucose monitor (CGM) in the ICU. DESIGN Retrospective analysis. SETTING ICU of an academic medical center. PATIENTS Patients with COVID-19 on intravenous (IV) insulin. INTERVENTION After meeting initial validation criteria, CGM was used for IV insulin titration and POC BG was performed every 6 hours or as needed. MAIN OUTCOME MEASURES Outcomes included frequency of POC BG, workflow, safety, and accuracy measures. RESULTS The study included 19 patients, 18 with CGM data, mean age 58 years, 89% on mechanical ventilation, 37% on vasopressors, and 42% on dialysis. The median time to CGM validation was 137 minutes (interquartile range [IQR] 114-206). During IV insulin, the median number of POC values was 7 (IQR 6-16) on day 1, and declined slightly thereafter ( 71% reduction compared to standard of 24 /day). The median number of CGM values used nonadjunctively to titrate IV insulin was 11.5 (IQR 0, 15) on day 1 and increased thereafter. Time in range 70-180mg/dl was 64+/-23% on day 1 and 72+/-16% on day 2-7 while time <70 mg/dl was 1.5 +/-4.1% on day 1 and <1% on days 2-7. CONCLUSIONS This study provides data to support that CGM using a hybrid protocol is feasible, accurate, safe, and has potential to reduce nursing and staff workload.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date