Selected article for: "significant difference and statistical test"

Author: Chauvet, Dorian; Tran, Viet; Mutlu, Gurkan; George, Bernard; Allain, Jean-Marc
Title: Study of dural suture watertightness: an in vitro comparison of different sealants.
  • Cord-id: rvfmm21w
  • Document date: 2011_1_1
  • ID: rvfmm21w
    Snippet: BACKGROUND CSF leakages constitute a major complication of intradural procedures, especially for posterior fossa and skull base surgery. Dural suture watertightness is a decisive issue, and neurosurgeons routinely use different products to reinforce their dural closure. We have designed an experimental system capable of testing CSF leak pressure levels in order to compare two types of sutures in vitro and particularly four different sealants. METHODS Twenty-five fresh human cadaveric dural sampl
    Document: BACKGROUND CSF leakages constitute a major complication of intradural procedures, especially for posterior fossa and skull base surgery. Dural suture watertightness is a decisive issue, and neurosurgeons routinely use different products to reinforce their dural closure. We have designed an experimental system capable of testing CSF leak pressure levels in order to compare two types of sutures in vitro and particularly four different sealants. METHODS Twenty-five fresh human cadaveric dural samples were removed and prepared for testing in a pressure chamber system connected to a hydraulic pressure motor. CSF leak levels were objectively registered. First, simple interrupted stitches were compared to running simple closure on 50-mm linear suture. Secondly, four sealants (two sealants/glues, Bioglue®, Duraseal®; two haemostatics, Tachosil®, Tissucol®) were tested. Statistical analysis was performed with paired Student's t-test. RESULTS No significant difference between interrupted closure and running suture was observed (p = 0.079). All sealants increased the watertightness of the suture significatively. However, comparison of the means of the differences for each product revealed large variations. In the conditions of our experiment, one sealant (Duraseal®) and one haemostatic (Tachosil®) seemed to show better results. We observed two different types of leakage: at the dura-sealant interface and through the sealant itself. CONCLUSIONS We have developed an experimental device capable of testing dural closure watertightness. Interrupted stitch suturing seemed no different from running simple closure. On the contrary, the sealants tested show different watertightness capacities.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date