Author: Dou, Xiaowen; Wang, Enyun; Hu, Jiwen; Zong, Zengyan; Jiang, Ruiwei; Wang, Mengmeng; Kan, Lijuan; Zhang, Xiuming
Title: Comparison of three automatic chemiluminescent immunoassays for monitoring dynamic profile of SARSâ€CoVâ€2 IgG and IgM Cord-id: llxhmfsw Document date: 2020_12_19
ID: llxhmfsw
Snippet: BACKGROUND: Seldom performance evaluation and diagnosis comparison studies were reported for different chemiluminescent immunoassay (CLIA) kits approved under an emergency approval program for SARSâ€CoVâ€2 infection. METHODS: A total of 100 and 105 serum separately from nonâ€infected populations and COVIDâ€19 patients were detected with SARSâ€CoVâ€2 IgM and IgG kits. The characteristics including precision, functional sensitivity, linearity, and accuracy were evaluated for Axceed, iFlash,
Document: BACKGROUND: Seldom performance evaluation and diagnosis comparison studies were reported for different chemiluminescent immunoassay (CLIA) kits approved under an emergency approval program for SARSâ€CoVâ€2 infection. METHODS: A total of 100 and 105 serum separately from nonâ€infected populations and COVIDâ€19 patients were detected with SARSâ€CoVâ€2 IgM and IgG kits. The characteristics including precision, functional sensitivity, linearity, and accuracy were evaluated for Axceed, iFlash, and Maglumi CLIA kits. RESULTS: Maglumi and iFlash had the best analytical sensitivity for IgM and IgG, respectively. Axceed kits had a linearity response in the detected concentration. The clinical sensitivity of Axceed, iFlash, and Maglumi was 68.0%, 64.9%, and 63.9% with a specificity of 99.0%, 96.0%, and 100% for IgM, 85.6%, 97.9%, and 94.8% with a specificity of 97.0% for IgG. ROC analysis indicated all kits had a diagnostic power greater than 0.9. Notably, either IgM or IgG kits obtained a poor agreement (Kappa value from 0.397 to 0.713) with others. Among 38 recovered patients, 94.7% had an effective immune response, and both seropositive IgM and IgG accounted for the biggest proportion (medium, 42 days onset), then followed by the single seropositive IgG (medium, 50 days onset) in Ab profile. CONCLUSION: The performance of CLIA kits satisfied the diagnosis of SARSâ€CoVâ€2 infection. Both positive of IgG and IgM contributes to improve the specificity, and a positive one will enhance the sensitivity.
Search related documents:
Co phrase search for related documents- accurate diagnosis and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72
- accurate diagnosis and low negative: 1, 2, 3, 4, 5, 6
- acid result and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21
- acid result and low negative: 1
- acid testing and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72
- acid testing and low negative: 1, 2, 3
- acute respiratory syndrome and low negative: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29
- acute respiratory syndrome and maglumi iflash: 1, 2
- acute respiratory syndrome and maglumi igg: 1, 2, 3
Co phrase search for related documents, hyperlinks ordered by date