Author: Sanchita Bhadra; Timothy E Riedel; Simren Lakhotia; Nicholas D Tran; Andrew D Ellington
Title: High-surety isothermal amplification and detection of SARS-CoV-2, including with crude enzymes Document date: 2020_4_14
ID: ezv6xp16_16
Snippet: Given the low limits of detection we have observed, it is possible that LAMP-OSD might be used as part of diagnostics pipelines, or in direct patient screening. However, for this the reactions would need to operate under conditions commensurate with sample collection, especially in resource poor settings. Collection of nasopharyngeal and oropharyngeal swab specimens causes considerable discomfort to patients and requires supplies in the form of s.....
Document: Given the low limits of detection we have observed, it is possible that LAMP-OSD might be used as part of diagnostics pipelines, or in direct patient screening. However, for this the reactions would need to operate under conditions commensurate with sample collection, especially in resource poor settings. Collection of nasopharyngeal and oropharyngeal swab specimens causes considerable discomfort to patients and requires supplies in the form of sterile swabs and transport media. Moreover, these samples are relatively difficult to self-collect. In contrast, saliva can be non-invasively collected simply by spitting in a sterile collection vessel and it can be done just as easily in a clinic as well as at home. Moreover, studies have shown that SARS-CoV-2 can be consistently detected in patient saliva with median viral loads of 3.3 × 10 6 copies/mL. 25 We tested the direct sample analysis ability of individual and multiplex LAMP-OSD assays by seeding them with 3 µL of human saliva spiked with SARS-CoV-2 virions. As control, duplicate LAMP-OSD reactions were seeded with virions suspended in 3 µL of TE buffer. Following 90 min incubation at 65 °C, endpoint observation of presence or absence of OSD fluorescence revealed that all assays seeded with SARS-CoV-2 virions, whether in human saliva or TE buffer, were brightly fluorescent (Figure 6 ). In contrast, assays lacking specific templates remained dark. These results suggest that LAMP-OSD assays might be used for direct analysis of human saliva samples in order to amplify and detect genetic signatures from SARS-CoV-2 virions.
Search related documents:
Co phrase search for related documents- absence presence and considerable discomfort: 1
- absence presence and considerable discomfort cause: 1
- absence presence and direct analysis: 1, 2
- absence presence and human saliva: 1
- absence presence and LAMP osd: 1, 2, 3
- absence presence and LAMP OSD assay: 1
- detection low limit and direct analysis: 1
- detection low limit and human saliva: 1
- direct analysis and human saliva: 1, 2, 3, 4
- direct analysis and LAMP osd: 1, 2, 3, 4, 5
- direct analysis and LAMP OSD assay: 1
- endpoint observation and LAMP osd: 1, 2
- endpoint observation and LAMP OSD assay: 1, 2
- human saliva and LAMP osd: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- human saliva and LAMP OSD assay: 1, 2
- human saliva sample and LAMP osd: 1
Co phrase search for related documents, hyperlinks ordered by date