Selected article for: "Try single phrases listed below for"

Author: Rong, Lisa Q; Hameed, Irbaz; Di Franco, Antonino; Rahouma, Mohamed M; Khan, Faiza M; Demetres, Michelle; Weinsaft, Jonathan W; Devereux, Richard B; Gaudino, Mario
Title: A pairwise meta-analytic comparison of aortic valve area determined by planimetric versus hemodynamic methods in aortic stenosis.
  • Cord-id: vtez01ri
  • Document date: 2020_9_8
  • ID: vtez01ri
    Snippet: BACKGROUND Aortic valve area (AVA) is commonly determined from 2-dimensional transthoracic echocardiography (2D TTE) by continuity equation; however, this method relies on geometric assumptions of the left ventricular outflow tract which may not hold true. This study compared mean differences and correlations for AVA by planimetric (2-dimensional transesophageal echocardiography [2D TEE], 3-dimensional transesophageal echocardiography [3D TEE], 3-dimensional transthoracic echocardiography [3D TT
    Document: BACKGROUND Aortic valve area (AVA) is commonly determined from 2-dimensional transthoracic echocardiography (2D TTE) by continuity equation; however, this method relies on geometric assumptions of the left ventricular outflow tract which may not hold true. This study compared mean differences and correlations for AVA by planimetric (2-dimensional transesophageal echocardiography [2D TEE], 3-dimensional transesophageal echocardiography [3D TEE], 3-dimensional transthoracic echocardiography [3D TTE], multi-detector computed tomography [MDCT], and magnetic resonance imaging [MRI]) with hemodynamic methods (2D TTE and catheterization) using pairwise meta-analysis. METHOD Ovid MEDLINE®, Ovid EMBASE, and The Cochrane Library (Wiley) were queried for studies comparing AVA measurements assessed by planimetric and hemodynamic techniques. Pairwise meta-analysis for mean differences (using random effect model) and for correlation coefficients (r) were performed. RESULTS Forty-five studies (3014 patients) were included. Mean differences between planimetric and hemodynamic techniques were 0.12 cm2 (95%CI 0.10-0.15) for AVA (pooled r = 0.84; 95%CI 0.76-0.90); 1.36cm2 (95%CI 1.03-1.69) for left ventricular outflow tract area; and 0.13 cm (95%CI 0.07-0.20) for annular diameter (pooled r = 0.76; 95% CI 0.64-0.94); 0.67 cm2 (95%CI 0.59-0.76) for annular area (pooled r = 0.74; 95%CI 0.55-0.86). CONCLUSIONS Planimetric techniques slightly, but significantly, overestimate AVA when compared to hemodynamic techniques.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date