Author: Zhang, Feng; Chen, Jia; Huang, He; Deng, Xiaolong; Zhang, Wei; Zeng, Min; Liu, Rangjiao; Dai, Lizhong; Wan, Qiquan
                    Title: Application of metagenomic next-generation sequencing in the diagnosis and treatment guidance of Pneumocystis jirovecii pneumonia in renal transplant recipients  Cord-id: yem2ngbq  Document date: 2021_4_21
                    ID: yem2ngbq
                    
                    Snippet: Pneumocystis jirovecii pneumonia (PJP) is difficult to be diagnosed, so this study explored if PJP could be diagnosed by metagenomic next-generation sequencing (mNGS) and if mNGS could guide the therapy of PJP. mNGS was successfully diagnosed 13 out of 14 PJP recipients with 11 through peripheral blood samples, verified by PCR. Ten non-PJP recipients were enrolled as the control group. Blood tests revealed a high β-D-glucan (BDG) level in all recipients with PJP during the hospitalization. Four
                    
                    
                    
                     
                    
                    
                    
                    
                        
                            
                                Document: Pneumocystis jirovecii pneumonia (PJP) is difficult to be diagnosed, so this study explored if PJP could be diagnosed by metagenomic next-generation sequencing (mNGS) and if mNGS could guide the therapy of PJP. mNGS was successfully diagnosed 13 out of 14 PJP recipients with 11 through peripheral blood samples, verified by PCR. Ten non-PJP recipients were enrolled as the control group. Blood tests revealed a high β-D-glucan (BDG) level in all recipients with PJP during the hospitalization. Four (28.6%) of 14 PJP patients were infected with cytomegalovirus simultaneously, while 8 (57.1%) suffered from a combined infection caused by Torque teno virus. Five (35.7%) of 14 cases died of PJP or the subsequent bacteremias/bacterial pneumonia with a longer interval between the onset and diagnosis of/the available therapy against PJP than survival cases. Univariate analysis of characteristics between PJP and non-PJP recipients revealed that BDG assays was higher at the admission in PJP group (P =0.011). This present study supports the value of mNGS detection of blood sample in diagnosing PJP, which could assist clinical decision for therapy against PJ and improve outcome of PJP. The study also highlights the sensitivity of BDG assays. Cytomegalovirus and Torque teno virus infections often occur at the same time of PJP, thus can be alerts of PJP.
 
  Search related documents: 
                                Co phrase  search for related documents- absolute lymphocyte count and acute ards respiratory distress syndrome: 1, 2
  - absolute lymphocyte count and admission procalcitonin: 1
  - absolute lymphocyte count and low sensitivity: 1
  - absolute lymphocyte count and lymphocyte count: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73
  - absolute lymphocyte count severe lymphopenia and lymphocyte count: 1, 2, 3
  - absolute value and acid extraction: 1, 2
  - absolute value and acute ards respiratory distress syndrome: 1
  - absolute value and lymphocyte count: 1, 2, 3, 4, 5, 6, 7, 8, 9
  - acid detection kit and lymphocyte count: 1
  
 
                                Co phrase  search for related documents, hyperlinks ordered by date