Selected article for: "complex assembly and IFIT complex"

Author: Renata C Fleith; Harriet V Mears; Edward Emmott; Stephen C Graham; Daniel S Mansur; Trevor R Sweeney
Title: IFIT3 and IFIT2/3 promote IFIT1-mediated translation inhibition by enhancing binding to non-self RNA
  • Document date: 2018_2_8
  • ID: j97gul0w_15
    Snippet: Proteins/complexes were injected (100 L at the concentration described in IFIT complex assembly, above) onto an analytical Superdex 200 Increase 10/300 gel filtration column. MALS analysis was performed at room temperature, by inline measurement of static light scattering (DAWN 8+, Wyatt Technology), differential refractive index (Optilab T-rEX, Wyatt Technology), and 280 nm absorbance (Agilent 1260 UV, Agilent Technologies) following SEC at a.....
    Document: Proteins/complexes were injected (100 L at the concentration described in IFIT complex assembly, above) onto an analytical Superdex 200 Increase 10/300 gel filtration column. MALS analysis was performed at room temperature, by inline measurement of static light scattering (DAWN 8+, Wyatt Technology), differential refractive index (Optilab T-rEX, Wyatt Technology), and 280 nm absorbance (Agilent 1260 UV, Agilent Technologies) following SEC at a flow rate of 0.4 mL/min. Molecular masses were calculated using the ASTRA6 software package (Wyatt Technology).

    Search related documents:
    Co phrase search for related documents
    • complex assembly and IFIT complex assembly: 1, 2, 3, 4, 5, 6
    • complex assembly and ml min flow rate: 1
    • complex assembly and protein complex: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26
    • complex assembly and software package: 1
    • flow rate and IFIT complex assembly: 1
    • flow rate and light scatter: 1
    • flow rate and ml min flow rate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73, 74
    • flow rate and nm absorbance: 1
    • flow rate and refractive index: 1
    • flow rate and room temperature: 1, 2, 3, 4, 5, 6, 7
    • flow rate and software package: 1
    • gel filtration and nm absorbance: 1, 2
    • gel filtration and room temperature: 1, 2, 3, 4, 5
    • gel filtration column and nm absorbance: 1, 2
    • gel filtration column and room temperature: 1, 2, 3
    • IFIT complex assembly and ml min flow rate: 1
    • MALS analysis and nm absorbance: 1
    • MALS analysis and refractive index: 1, 2