Selected article for: "filtration column and room temperature"

Author: Renata C Fleith; Harriet V Mears; Edward Emmott; Stephen C Graham; Daniel S Mansur; Trevor R Sweeney
Title: IFIT3 and IFIT2/3 promote IFIT1-mediated translation inhibition by enhancing binding to non-self RNA
  • Document date: 2018_2_8
  • ID: j97gul0w_15
    Snippet: Proteins/complexes were injected (100 L at the concentration described in IFIT complex assembly, above) onto an analytical Superdex 200 Increase 10/300 gel filtration column. MALS analysis was performed at room temperature, by inline measurement of static light scattering (DAWN 8+, Wyatt Technology), differential refractive index (Optilab T-rEX, Wyatt Technology), and 280 nm absorbance (Agilent 1260 UV, Agilent Technologies) following SEC at a.....
    Document: Proteins/complexes were injected (100 L at the concentration described in IFIT complex assembly, above) onto an analytical Superdex 200 Increase 10/300 gel filtration column. MALS analysis was performed at room temperature, by inline measurement of static light scattering (DAWN 8+, Wyatt Technology), differential refractive index (Optilab T-rEX, Wyatt Technology), and 280 nm absorbance (Agilent 1260 UV, Agilent Technologies) following SEC at a flow rate of 0.4 mL/min. Molecular masses were calculated using the ASTRA6 software package (Wyatt Technology).

    Search related documents:
    Co phrase search for related documents
    • complex assembly and IFIT complex assembly: 1, 2, 3, 4, 5, 6
    • complex assembly and ml min flow rate: 1
    • complex assembly and protein complex: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • flow rate and IFIT complex assembly: 1
    • flow rate and light scatter: 1
    • flow rate and ml min flow rate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • flow rate and nm absorbance: 1
    • flow rate and refractive index: 1
    • flow rate and room temperature: 1, 2, 3, 4, 5, 6, 7
    • gel filtration and nm absorbance: 1, 2
    • gel filtration and room temperature: 1, 2, 3, 4, 5
    • gel filtration column and nm absorbance: 1, 2
    • gel filtration column and room temperature: 1, 2, 3
    • IFIT complex assembly and ml min flow rate: 1
    • MALS analysis and nm absorbance: 1
    • MALS analysis and refractive index: 1, 2
    • ml min flow rate and nm absorbance: 1
    • ml min flow rate and refractive index: 1
    • ml min flow rate and room temperature: 1, 2, 3, 4, 5