Selected article for: "additional information and low classification"

Author: Olsen, Markus Harboe; Jensen, Helene Ravnholt; Ebdrup, Søren Røddik; Topp, Nina Hvid; Strange, Ditte Gry; Møller, Kirsten; Kondziella, Daniel
Title: Automated pupillometry and the FOUR score — what is the diagnostic benefit in neurointensive care?
  • Cord-id: afcmln4w
  • Document date: 2020_5_7
  • ID: afcmln4w
    Snippet: INTRODUCTION: The Glasgow Coma Scale (GCS) and visual inspection of pupillary function are routine measures to monitor patients with impaired consciousness and predict their outcome in the neurointensive care unit (neuro-ICU). Our aim was to compare more recent measures, i.e. FOUR score and automated pupillometry, to standard monitoring with the GCS and visual inspection of pupils. METHODS: Supervised trained nursing staff examined a consecutive sample of patients admitted to the neuro-ICU of a
    Document: INTRODUCTION: The Glasgow Coma Scale (GCS) and visual inspection of pupillary function are routine measures to monitor patients with impaired consciousness and predict their outcome in the neurointensive care unit (neuro-ICU). Our aim was to compare more recent measures, i.e. FOUR score and automated pupillometry, to standard monitoring with the GCS and visual inspection of pupils. METHODS: Supervised trained nursing staff examined a consecutive sample of patients admitted to the neuro-ICU of a tertiary referral centre using GCS and FOUR score and assessing pupillary function first by visual inspection and then by automated pupillometry. Clinical outcome was evaluated 6 months after admission using the Glasgow Outcome Scale-Extended. RESULTS: Fifty-six consecutive patients (median age 63 years) were assessed a total of 234 times. Of the 36 patients with at least one GCS score of 3, 13 had a favourable outcome. All seven patients with at least one FOUR score of ≤ 3 had an unfavourable outcome, which was best predicted by a low “brainstem” sub-score. Compared to automated pupillometry, visual assessment underestimated pupillary diameters (median difference, 0.4 mm; P = 0.006). Automated pupillometry detected a preserved pupillary light reflex in 10 patients, in whom visual inspection had missed pupillary constriction. DISCUSSION: Training of nursing staff to implement frequent monitoring of patients in the neuro-ICU with FOUR score and automated pupillometry is feasible. Both measures provide additional clinical information compared to the GCS and visual assessment of pupillary function, most importantly a more granular classification of patients with low levels of consciousness by the FOUR score.

    Search related documents:
    Co phrase search for related documents
    • absence presence and additional clinical information: 1
    • absence presence and logistic regression: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • absent present and logistic regression: 1, 2, 3
    • absolute difference and logistic regression: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
    • abstract screening and acute brain injury: 1
    • abstract screening and logistic regression: 1, 2, 3, 4
    • acute brain injury and logistic regression: 1, 2
    • additional clinical information and logistic regression: 1