Selected article for: "Try single phrases listed below for"

Author: Kagiyama, Nobuyuki; Hiki, Makoto; Matsue, Yuya; Dohi, Tomotaka; Matsuzawa, Wataru; Daida, Hiroyuki; Minamino, Tohru; Kasai, Takatoshi
Title: Validation of telemedicine-based self-assessment of vital signs for patients with COVID-19: A pilot study.
  • Cord-id: p1noqoj2
  • Document date: 2021_5_9
  • ID: p1noqoj2
    Snippet: INTRODUCTION In the ongoing COVID-19 pandemic, the development of a system that would prevent the infection of healthcare providers is in urgent demand. We sought to investigate the feasibility and validity of a telemedicine-based system in which healthcare providers remotely check the vital signs measured by patients with COVID-19. METHODS Patients hospitalized with confirmed or suspected COVID-19 measured and uploaded their vital signs to secure cloud storage. Additionally, the respiratory rat
    Document: INTRODUCTION In the ongoing COVID-19 pandemic, the development of a system that would prevent the infection of healthcare providers is in urgent demand. We sought to investigate the feasibility and validity of a telemedicine-based system in which healthcare providers remotely check the vital signs measured by patients with COVID-19. METHODS Patients hospitalized with confirmed or suspected COVID-19 measured and uploaded their vital signs to secure cloud storage. Additionally, the respiratory rates were monitored using a mat-type sensor placed under the bed. We assessed the time until the values became available on the Cloud and the agreements between the patient-measured vital signs and simultaneous healthcare provider measurements. RESULTS Between 26 May-23 September 2020, 3835 vital signs were measured and uploaded to the cloud storage by the patients (n=16, median 72 years old, 31% women). All patients successfully learned how to use these devices with a 10-minute lecture. The median time until the measurements were available on the cloud system was only 0.35 min, and 95.2% of the vital signs were available within 5 min of the measurement. The agreement between the patients' and healthcare providers' measurements was excellent for all parameters. Interclass coefficient correlations were as follows: systolic (0.92, p<0.001), diastolic blood pressure (0.86, p<0.001), heart rate (0.89, p<0.001), peripheral oxygen saturation (0.92, p<0.001), body temperature (0.83, p<0.001), and respiratory rates (0.90, p<0.001). CONCLUSIONS Telemedicine-based self-assessment of vital signs in patients with COVID-19 was feasible and reliable. The system will be a useful alternative to traditional vital sign measurements by healthcare providers during the COVID-19 pandemic.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date