Selected article for: "average number and clinical study"

Author: Levine, David; Petroski, Gregory F; Haertling, Tracy; Beaudoin, Teresa
Title: Electrostatic Precipitation in Low Pressure Laparoscopic Hysterectomy and Myomectomy.
  • Cord-id: pas5ilrj
  • Document date: 2020_1_1
  • ID: pas5ilrj
    Snippet: Background and Objective The purpose of this study was to evaluate the impact of using electrostatic precipitation to manage the surgical plume during low pressure laparoscopic gynecologic procedures. Methods This was a prospective, blinded, randomized controlled study of women with a clinical indication for laparoscopic hysterectomy (n = 30) or myomectomy (n = 5). Patients were randomized to either use electrostatic precipitation (EP) during the procedure, or not (No EP, hysterectomy group only
    Document: Background and Objective The purpose of this study was to evaluate the impact of using electrostatic precipitation to manage the surgical plume during low pressure laparoscopic gynecologic procedures. Methods This was a prospective, blinded, randomized controlled study of women with a clinical indication for laparoscopic hysterectomy (n = 30) or myomectomy (n = 5). Patients were randomized to either use electrostatic precipitation (EP) during the procedure, or not (No EP, hysterectomy group only). Results Low pressure surgery could be undertaken in 87% of hysterectomy cases (13/15) when using EP to manage the surgical plume, compared to only 53% (8/15) in the No EP group. Overall average rating of the visual field was excellent with EP vs fair for No EP. Average CO2 consumption was reduced by 29% when using EP (16.7L vs 23.5L, p = 0.152). The average number of procedural pauses to vent smoke was lower with EP than the No EP group (1.5 per case vs. 3.7 per case, p = 0.005). Average procedure duration for the EP vs No EP group was 40.5 min vs. 46.9 min (p = 0.987). There were no measurable differences between groups for body temperature, end-tidal CO2, and discharge pain scores. In myomectomy, all five cases could be performed at low pressure, with an excellent visual field rating. Conclusion Electrostatic precipitation enhances low pressure laparoscopic hysterectomy and myomectomy. This was achieved by minimizing interruptions to surgery and exchange of CO2; providing a clear visual field throughout the procedure; and eliminating surgical smoke at the site of origin.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1