Selected article for: "human enterovirus and RSV respiratory syncytial virus"

Author: Babady, N. Esther; England, Matthew R.; Jurcic Smith, Kristen L.; He, Taojun; Wijetunge, Dona Saumya; Tang, Yi-Wei; Chamberland, Robin R.; Menegus, Marilyn; Swierkosz, Ella M.; Jerris, Robert C.; Greene, Wallace
Title: Multicenter Evaluation of the ePlex Respiratory Pathogen Panel for the Detection of Viral and Bacterial Respiratory Tract Pathogens in Nasopharyngeal Swabs
  • Cord-id: ptyw4hqw
  • Document date: 2018_1_24
  • ID: ptyw4hqw
    Snippet: The performance of the new ePlex Respiratory Pathogen (RP) panel (GenMark Diagnostics) for the simultaneous detection of 19 viruses (influenza A virus; influenza A H1 virus; influenza A 2009 H1 virus; influenza A H3 virus; influenza B virus; adenovirus; coronaviruses [HKU1, OC43, NL63, and 229E]; human rhinovirus/enterovirus; human metapneumovirus; parainfluenza viruses 1, 2, 3, and 4; and respiratory syncytial virus [RSV] [RSV subtype A and RSV subtype B]) and 2 bacteria (Mycoplasma pneumoniae
    Document: The performance of the new ePlex Respiratory Pathogen (RP) panel (GenMark Diagnostics) for the simultaneous detection of 19 viruses (influenza A virus; influenza A H1 virus; influenza A 2009 H1 virus; influenza A H3 virus; influenza B virus; adenovirus; coronaviruses [HKU1, OC43, NL63, and 229E]; human rhinovirus/enterovirus; human metapneumovirus; parainfluenza viruses 1, 2, 3, and 4; and respiratory syncytial virus [RSV] [RSV subtype A and RSV subtype B]) and 2 bacteria (Mycoplasma pneumoniae and Chlamydia pneumoniae) was evaluated. Prospectively and retrospectively collected nasopharyngeal swab (NPS) specimens (n = 2,908) were evaluated by using the ePlex RP panel, with the bioMérieux/BioFire FilmArray Respiratory Panel (BioFire RP) as the comparator method. Discordance analysis was performed by using target-specific PCRs and bidirectional sequencing. The reproducibility of the assay was evaluated by using reproducibility panels comprised of 6 pathogens. The overall agreement between the ePlex RP and BioFire RP results was >95% for all targets. Positive percent agreement with the BioFire RP result for viruses ranged from 85.1% (95% confidence interval [CI], 80.2% to 88.9%) to 95.1% (95% CI, 89.0% to 97.9%), while negative percent agreement values ranged from 99.5% (95% CI, 99.1% to 99.7%) to 99.8% (95% CI, 99.5% to 99.9%). Additional testing of discordant targets (12%; 349/2,908) confirmed the results of ePlex RP for 38% (131/349) of samples tested. Reproducibility was 100% for all targets tested, with the exception of adenovirus, for which reproducibilities were 91.6% at low virus concentrations and 100% at moderate virus concentrations. The ePlex RP panel offers a new, rapid, and sensitive “sample-to-answer” multiplex panel for the detection of the most common viral and bacterial respiratory pathogens.

    Search related documents:
    Co phrase search for related documents
    • accurate rapid and additional testing: 1
    • accurate rapid and additional testing require: 1
    • accurate rapid and adenovirus detection: 1, 2
    • accurate rapid and lod detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
    • accurate rapid and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
    • accurate rapid and low pathogen: 1, 2, 3
    • accurate rapid and low pathogen load: 1
    • accurate rapid diagnosis and acid testing: 1, 2
    • accurate rapid diagnosis and adenovirus detection: 1, 2
    • accurate rapid diagnosis and lod detection: 1, 2, 3, 4
    • accurate rapid diagnosis and lod detection limit: 1, 2, 3, 4
    • accurately rapidly and additional testing: 1
    • acid testing and additional testing: 1, 2, 3, 4, 5, 6
    • acid testing and adenovirus detection: 1
    • acid testing and lod detection: 1, 2, 3, 4, 5, 6, 7
    • acid testing and lod detection limit: 1, 2, 3, 4, 5, 6
    • acid testing and low pathogen: 1
    • acid testing and low pathogen load: 1
    • additional testing and low pathogen load: 1