Title: In-silico immune cell deconvolution of the airway proteomes of infants with pneumonia reveals a link between reduced airway eosinophils and an increased risk of mortality
  • Document date: 2019_11_13
  • ID: h1zkka8p_19
    Snippet: Each LC run was finished by washout with 98% B for 10 min and re-equilibration in 2% B for 30 min. Five blanks of 40 min each were run on the column between each injection comprising of two wash cycles with 90% B and an equilibration phase of 15 min to avoid sample carryover. Peptides were measured using a Q Exactive Orbitrap mass spectrometer (Thermo Scientific, USA) coupled to the chromatography system via a nano-electrospray ion source (Thermo.....
    Document: Each LC run was finished by washout with 98% B for 10 min and re-equilibration in 2% B for 30 min. Five blanks of 40 min each were run on the column between each injection comprising of two wash cycles with 90% B and an equilibration phase of 15 min to avoid sample carryover. Peptides were measured using a Q Exactive Orbitrap mass spectrometer (Thermo Scientific, USA) coupled to the chromatography system via a nano-electrospray ion source (Thermo Scientific). On the Q Exactive , the ms^1 settings for peptides were: Resolution, 70000; AGC target, 3e6; maximum IT, 120 ms; scan range, 400-1800 m/z; while the ms^2 settings for fragmentation spectra of peptides were:

    Search related documents:
    Co phrase search for related documents
    • AGC target and equilibration 10 min: 1
    • AGC target and equilibration phase: 1
    • AGC target and ion source: 1
    • AGC target and lc run: 1
    • AGC target and mass spectrometer: 1, 2, 3
    • AGC target and nano electrospray: 1, 2
    • AGC target and nano electrospray Thermo Scientific ion source: 1
    • AGC target and Orbitrap mass spectrometer: 1, 2, 3
    • AGC target and sample carryover avoid: 1
    • AGC target and Thermo Scientific ion source: 1
    • AGC target and USA Thermo Scientific Orbitrap mass spectrometer: 1
    • chromatography system and equilibration phase: 1
    • chromatography system and mass spectrometer: 1, 2, 3, 4, 5, 6
    • chromatography system and nano electrospray: 1
    • chromatography system and nano electrospray Thermo Scientific ion source: 1
    • chromatography system and Orbitrap mass spectrometer: 1, 2, 3, 4, 5
    • chromatography system and sample carryover avoid: 1
    • chromatography system and Thermo Scientific ion source: 1
    • chromatography system and USA Thermo Scientific Orbitrap mass spectrometer: 1