Selected article for: "Try single phrases listed below for"

Author: Razavi, Mahmood K; Jaff, Michael R; Miller, Larry E
Title: Safety and Effectiveness of Stent Placement for Iliofemoral Venous Outflow Obstruction: Systematic Review and Meta-Analysis.
  • Cord-id: e3n48zr7
  • Document date: 2015_1_1
  • ID: e3n48zr7
    Snippet: BACKGROUND Endovenous recanalization of iliofemoral stenosis or occlusion with angioplasty and stent placement has been increasingly used to maintain long-term venous patency in patients with iliofemoral venous outflow obstruction. The purpose of this systematic review and meta-analysis was to determine safety and effectiveness of venous stent placement in patients with iliofemoral venous outflow obstruction. METHODS AND RESULTS We searched MEDLINE and EMBASE for studies evaluating safety or eff
    Document: BACKGROUND Endovenous recanalization of iliofemoral stenosis or occlusion with angioplasty and stent placement has been increasingly used to maintain long-term venous patency in patients with iliofemoral venous outflow obstruction. The purpose of this systematic review and meta-analysis was to determine safety and effectiveness of venous stent placement in patients with iliofemoral venous outflow obstruction. METHODS AND RESULTS We searched MEDLINE and EMBASE for studies evaluating safety or effectiveness of stent placement in patients with iliofemoral venous outflow obstruction. Data were extracted by disease pathogenesis: nonthrombotic, acute thrombotic, or chronic post-thrombotic. Main outcomes included technical success, periprocedural complications, symptom relief at final follow-up, and primary/secondary patency through 5 years. A total of 37 studies reporting 45 treatment effects (nonthrombotic, 8; acute thrombotic, 19; and chronic post-thrombotic, 18) from 2869 patients (nonthrombotic, 1122; acute thrombotic, 629; and chronic post-thrombotic, 1118) were included. Technical success rates were comparable among groups, ranging from 94% to 96%. Complication rates ranged from 0.3% to 1.1% among groups for major bleeding, from 0.2% to 0.9% for pulmonary embolism, from 0.1% to 0.7% for periprocedural mortality, and from 1.0% to 6.8% for early thrombosis. Patient symptom relief data were reported inconsistently. At 1 year, primary and secondary patency were 96% and 99% for nonthrombotic, 87% and 89% for acute thrombotic, and 79% and 94% for chronic post-thrombotic. CONCLUSIONS Stent placement for iliofemoral venous outflow obstruction results in high technical success and acceptable complication rates regardless of cause of obstruction.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1