Selected article for: "multiplex RT PCR assay and RT PCR assay"

Author: Cassinari, Kévin; Alessandri-Gradt, Elodie; Chambon, Pascal; Charbonnier, Françoise; Gracias, Ségolène; Beaussire, Ludivine; Alexandre, Kevin; Sarafan-Vasseur, Nasrin; Houdayer, Claude; Etienne, Manuel; Caron, François; Plantier, Jean Christophe; Frebourg, Thierry
Title: Assessment of multiplex digital droplet RT-PCR as a diagnostic tool for SARS-CoV-2 detection in nasopharyngeal swabs and saliva samples
  • Cord-id: qgytzq06
  • Document date: 2021_1_2
  • ID: qgytzq06
    Snippet: BACKGROUND: Reverse transcription-quantitative PCR on nasopharyngeal swabs is currently the reference COVID-19 diagnosis method but exhibits imperfect sensitivity. METHODS: We developed a multiplex reverse transcription-digital droplet PCR (RT-ddPCR) assay, targeting six SARS-CoV-2 genomic regions, and evaluated it on nasopharyngeal swabs and saliva samples collected from 130 COVID-19 positive or negative ambulatory individuals, who presented symptoms suggestive of mild or moderate SARS-CoV2 inf
    Document: BACKGROUND: Reverse transcription-quantitative PCR on nasopharyngeal swabs is currently the reference COVID-19 diagnosis method but exhibits imperfect sensitivity. METHODS: We developed a multiplex reverse transcription-digital droplet PCR (RT-ddPCR) assay, targeting six SARS-CoV-2 genomic regions, and evaluated it on nasopharyngeal swabs and saliva samples collected from 130 COVID-19 positive or negative ambulatory individuals, who presented symptoms suggestive of mild or moderate SARS-CoV2 infection. RESULTS: For the nasopharyngeal swab samples, the results obtained using the 6-plex RT-ddPCR and RT-qPCR assays were all concordant. The 6-plex RT-ddPCR assay was more sensitive than RT-qPCR (85% versus 62%) on saliva samples from patients with positive nasopharyngeal swabs. CONCLUSION: Multiplex RT-ddPCR represents an alternative and complementary tool for the diagnosis of COVID-19, in particular to control RT-qPCR ambiguous results. It can also be applied to saliva for repetitive sampling and testing individuals for whom nasopharyngeal swabbing is not possible.

    Search related documents:
    Co phrase search for related documents
    • absolute quantification and low sensitivity: 1
    • accurate detection and low contain: 1
    • accurate detection and low sensitivity: 1, 2, 3, 4, 5, 6
    • additional target and load sample: 1
    • additional target and low sensitivity: 1
    • load sample and low sensitivity: 1, 2, 3, 4
    • load sample and low viral load sample: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11