Author: Hung, Lien-Yu; Huang, Tze-Bin; Tsai, Yi-Che; Yeh, Chen-Sheng; Lei, Huan-Yao; Lee, Gwo-Bin
Title: A microfluidic immunomagnetic bead-based system for the rapid detection of influenza infections: from purified virus particles to clinical specimens Cord-id: hn705g9k Document date: 2013_2_19
ID: hn705g9k
Snippet: Seasonal and novel influenza infections have the potential to cause worldwide pandemics. In order to properly treat infected patients and to limit its spread, a rapid, accurate and automatic influenza diagnostic tool needs to be developed. This study therefore presents a new integrated microfluidic system for the rapid detection of influenza infections. It integrated a suction-type, pneumatic-driven microfluidic control module, a magnetic bead-based fluorescent immunoassay (FIA) and an end-point
Document: Seasonal and novel influenza infections have the potential to cause worldwide pandemics. In order to properly treat infected patients and to limit its spread, a rapid, accurate and automatic influenza diagnostic tool needs to be developed. This study therefore presents a new integrated microfluidic system for the rapid detection of influenza infections. It integrated a suction-type, pneumatic-driven microfluidic control module, a magnetic bead-based fluorescent immunoassay (FIA) and an end-point optical detection module. This new system can successfully distinguish between influenza A and B using a single chip test within 15 min automatically, which is faster than existing devices. By utilizing the micromixers to thoroughly wash out the sputum-like mucus, this microfluidic system could be used for the diagnosis of clinical specimens and reduced the required sample volume to 40 μL. Furthermore, the results of diagnostic assays from 86 patient specimens have demonstrated that this system has 84.8 % sensitivity and 75.0 % specificity. This developed system may provide a powerful platform for the fast screening of influenza infections. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10544-013-9753-0) contains supplementary material, which is available to authorized users.
Search related documents:
Co phrase search for related documents- accurate detection and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- accurate detection and lod detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
- accurate detection and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- accurate rapid and acid detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- accurate rapid and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- accurate rapid and lod detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
- accurate rapid and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
- accurate rapid diagnostic method and acute respiratory syndrome: 1
- accurately detect and acid detection: 1, 2
- accurately detect and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
- accurately detect and lod detection: 1
- accurately diagnose and acid detection: 1, 2
- accurately diagnose and acute respiratory syndrome: 1, 2, 3, 4, 5
- acid detection and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acid detection and lod detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
- acid detection and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- acid detection and lod detection limit determine: 1
- acute respiratory syndrome and additional component: 1
- acute respiratory syndrome and loading chamber: 1
Co phrase search for related documents, hyperlinks ordered by date