Author: Van Hoovels, Lieve; Bossuyt, Xavier; Manfredi, Mariangela; Grossi, Valentina; Benucci, Maurizio; Van Den Bremt, Stefanie; De Baere, Heidi; Franceschi, Daria; Tosi, Emiliano; Meoni, Marco; Bizzaro, Nicola; Infantino, Maria
                    Title: Integrating quality assurance in autoimmunity: the changing face of the automated ANA IIF test.  Cord-id: i033pgnj  Document date: 2021_2_16
                    ID: i033pgnj
                    
                    Snippet: OBJECTIVES Currently available computer-aided diagnosis (CAD) systems for the detection of anti-nuclear antibodies (ANA) by indirect immunofluorescence (IIF) assay enable a standardized measurement of system-specific fluorescent intensity (FI) measures. We aimed to evaluate an internal quality control (iQC) program that controls the total ANA IIF process in routine practice. METHODS In addition to the kit iQC materials, supplemental quality indicators were integrated in a total quality assurance
                    
                    
                    
                     
                    
                    
                    
                    
                        
                            
                                Document: OBJECTIVES Currently available computer-aided diagnosis (CAD) systems for the detection of anti-nuclear antibodies (ANA) by indirect immunofluorescence (IIF) assay enable a standardized measurement of system-specific fluorescent intensity (FI) measures. We aimed to evaluate an internal quality control (iQC) program that controls the total ANA IIF process in routine practice. METHODS In addition to the kit iQC materials, supplemental quality indicators were integrated in a total quality assurance (QA) program: patient-derived iQC's samples (negative, 1/160 fine speckled and 1/160 homogeneous), median sample FI per run and percentage of ANA IIF positive samples per run.Analytical rejection criteria were based on the imprecision of the positivity index (PI) measure of the Zenit PRO system (Menarini). Clinical rejection criteria were based on changes in FI that correspond to a change in ANA IIF titer of ≥2. To evaluate the QA program, different artificial errors were introduced during the ANA IIF process. After every run, quality indicators were evaluated and compared to the pre-set target values. RESULTS Rescanning the ANA IIF slides five times, using an old conjugate and a needle obstruction resulted in analytically and even clinically relevant errors in ANA IIF results. All errors were correctly detected by the different defined quality indicators. Traditional Westgard rules, including analytically (and clinically) defined rejection limits were useful in monitoring quality indicators. CONCLUSIONS The integration of a total process iQC program in CAD systems, based on the specific FI measurands and performance criteria of the system, adds value to QA.
 
  Search related documents: 
                                Co phrase  search for related documents- Try single phrases listed below for: 1
  
 
                                Co phrase  search for related documents, hyperlinks ordered by date