Selected article for: "negative pool and positive pool"

Author: Dash, Girish Chandra; Rout, Usha Kiran; Nanda, Rashmi Ranjan; Parai, Debaprasad; Choudhary, Hari Ram; Kanungo, Srikanta; Palo, Subrata Kumar; Kshatri, Jaya Singh; Turuk, Jyotirmayee; Mishra, Bijaya Kumar; Pati, Sanghamitra; Bhattacharya, Debdutta
Title: Pooled testing for SARS‐CoV‐2 infection in an automated high‐throughput platform
  • Cord-id: wbki1ly8
  • Document date: 2021_6_28
  • ID: wbki1ly8
    Snippet: BACKGROUND: Active detection of SARS‐CoV‐2 infection through testing is elementary for the control of COVID‐19 pandemic. The implementation of large‐scale RT‐PCR testing has led to a rise in the demand for testing kits whose availability is always a concern. OBJECTIVE: To find out the feasibility of pooled testing in a high‐throughput platform. METHODOLOGY: Pooled testing was conducted in Roche cobas 6800 in 2 methods. Firstly, the simple two‐stage testing algorithm was conducted f
    Document: BACKGROUND: Active detection of SARS‐CoV‐2 infection through testing is elementary for the control of COVID‐19 pandemic. The implementation of large‐scale RT‐PCR testing has led to a rise in the demand for testing kits whose availability is always a concern. OBJECTIVE: To find out the feasibility of pooled testing in a high‐throughput platform. METHODOLOGY: Pooled testing was conducted in Roche cobas 6800 in 2 methods. Firstly, the simple two‐stage testing algorithm was conducted for 1410 samples individually and then as pooled samples. Secondly, we evaluated the sensitivity of cobas 6800 for the detection of a single positive sample within a pool of negative samples. RESULTS: Implementing the five‐sample Dorfman pooling to test 1410 samples, we identified 42 (2.9%) individual SARS‐CoV‐2‐positive samples and 27 (9.5%) positive pool samples. The pooling strategy precisely identified all the positive samples. All individually negative samples were also accurately determined by pooling. There was 100% sensitivity of detecting positive samples in a pool of negative samples even up to 1:64 dilution. There was a threefold increase in total throughput in one‐third of the cost per day. CONCLUSION: A high‐throughput platform such as Cobas 6800 can effectively increase the testing capacity by twofold to threefold by adopting the pooled testing strategy for successful management of SARS‐CoV‐2 and helping in the containment of community transmission.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date