Selected article for: "fit test and OSHA protocol"

Author: Amy DPhil Price; Yi Cui; Lei Liao; Wang Xiao; Xuanze Yu; Haotian Wang; Mervin Zhao; Qiqi Wang; Steven Chu; Larry F Chu
Title: Is the fit of N95 facial masks effected by disinfection? A study of heat and UV disinfection methods using the OSHA protocol fit test.
  • Document date: 2020_4_17
  • ID: b7n2og71_10
    Snippet: Work by others have evaluated the fit and function of masks after various disinfection treatments. These fit testing methods have utilized mannequin heads, and have used a small number of fit tests (usually 3) compared to the OSHA testing protocol for human fit testing (8 tests) . This is due to the fact that mannequin heads do not move. Humans model fit testing involves 8 tests, including: 1) normal breathing, 2) deep breathing, 3) turning the h.....
    Document: Work by others have evaluated the fit and function of masks after various disinfection treatments. These fit testing methods have utilized mannequin heads, and have used a small number of fit tests (usually 3) compared to the OSHA testing protocol for human fit testing (8 tests) . This is due to the fact that mannequin heads do not move. Humans model fit testing involves 8 tests, including: 1) normal breathing, 2) deep breathing, 3) turning the head left-to-right, 4) moving the head up-and-down, 5) talking, 6) grimacing, 7) bending over, and 8) normal breathing. Therefore, to our knowledge, there have not been any studies that have measured quantitative fit testing on heat-and UVGI-disinfected treated masks using a human model on the OSHA protocol. This would be the most accurate method to predict the fit performance of a mask on health care workers after disinfection. As authors of previous mannequin-based studies have stated as limitations of their studies, "These results should not be interpreted as being equivalent to a standard OSHAaccepted fit test method 11 Human subject testing is needed to truly assess respirator fit."

    Search related documents:
    Co phrase search for related documents
    • accurate method and human model: 1
    • deep breathing and fit test: 1, 2
    • deep breathing and fit testing: 1, 2
    • deep breathing and health care: 1, 2, 3
    • disinfection treatment and fit test: 1, 2
    • disinfection treatment and health care: 1, 2, 3, 4, 5, 6
    • disinfection treatment and human model: 1
    • fit performance and function fit: 1, 2
    • fit performance and health care: 1, 2, 3, 4, 5, 6, 7, 8
    • fit test and function fit: 1, 2, 3, 4
    • fit test and health care: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • fit test and health care worker: 1, 2
    • fit test and human fit testing: 1, 2
    • fit testing and function fit: 1, 2, 3
    • fit testing and health care: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • fit testing and health care worker: 1, 2, 3
    • fit testing and human fit testing: 1, 2, 3, 4, 5, 6
    • fit testing and human model: 1, 2
    • fit testing method and health care: 1