Author: Chen, Jonathan Hon-Kwan; Yip, Cyril Chik-Yan; Poon, Rosana Wing-Shan; Chan, Kwok-Hung; Cheng, Vincent Chi-Chung; Hung, Ivan Fan-Ngai; Chan, Jasper Fuk-Woo; Yuen, Kwok-Yung; To, Kelvin Kai-Wang
Title: Evaluating the use of posterior oropharyngeal saliva in a point-of-care assay for the detection of SARS-CoV-2 Cord-id: i65e5t5g Document date: 2020_6_14
ID: i65e5t5g
Snippet: During the Coronavirus disease 2019 (COVID-19) pandemic, logistic problems associated with specimen collection limited the SARS-CoV-2 testing, especially in the community. In this study, we assessed the use of posterior oropharyngeal saliva as specimens for the detection of SARS-CoV-2 in an automated point-of-care molecular assay. Archived nasopharyngeal swab (NPS) and posterior oropharyngeal saliva specimens of 58 COVID-19 patients were tested with the Xpert(®) Xpress SARS-CoV-2 assay. SARS-Co
Document: During the Coronavirus disease 2019 (COVID-19) pandemic, logistic problems associated with specimen collection limited the SARS-CoV-2 testing, especially in the community. In this study, we assessed the use of posterior oropharyngeal saliva as specimens for the detection of SARS-CoV-2 in an automated point-of-care molecular assay. Archived nasopharyngeal swab (NPS) and posterior oropharyngeal saliva specimens of 58 COVID-19 patients were tested with the Xpert(®) Xpress SARS-CoV-2 assay. SARS-CoV-2 was detected in either NPS or saliva specimens of all patients. Among them, 84.5% (49/58) tested positive in both NPS and saliva, 10.3% (6/58) tested positive in NPS only, and 5.2% (3/58) tested positive in saliva only. No significant difference in the detection rate was observed between NPS and saliva (McNemar’s test p = 0.5078). The detection rate was slightly higher for N2 (NPS 94.8% and Saliva 93.1%) than that of the E gene target (Saliva: 89.7% vs 82.8%) on both specimen types. Significantly earlier median Ct value was observed for NPS comparing to that of saliva on both E (26.8 vs 29.7, p = 0.0002) and N2 gene target (29.3 vs 32.3, p = 0.0002). The median Ct value of E gene target was significantly earlier than that of the N2 gene target for both NPS (26.8 vs 29.3, p < 0.0001) and saliva (29.7 vs 32.3, p < 0.0001). In conclusion, posterior oropharyngeal saliva and NPS were found to have similar detection rates in the point-of-care test for SARS-CoV-2 detection. Since posterior oropharyngeal saliva can be collected easily, the use of saliva as an alternative specimen type for SARS-CoV-2 detection is recommended.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date