Selected article for: "care point and molecular assay"

Author: Nguyen Van, J.-C.; Gerlier, C.; Pilmis, B.; Mizrahi, A.; Pean de Ponfilly, G.; khaterchi, A.; Enouf, V.; Ganansia, O.; Le Monnier, A.
Title: Prospective evaluation of ID NOW COVID-19 assay used as point-of-care test in an Emergency Department
  • Cord-id: vl7cs1sz
  • Document date: 2021_4_4
  • ID: vl7cs1sz
    Snippet: Background : Rapid testing for COVID-19 has been clearly identified as an essential component of the strategy to control the SARS-CoV-2 epidemic, worldwide. The ID NOW COVID-19 assay is a simple, user-friendly, rapid molecular biology test based on nicking and extension amplification reaction (NEAR). Objectives : The aim of this study was to evaluate the ID NOW COVID-19 assay when used as a point-of-care test (POCT) in our Emergency Department (ED). Type of study : This prospective study enrolle
    Document: Background : Rapid testing for COVID-19 has been clearly identified as an essential component of the strategy to control the SARS-CoV-2 epidemic, worldwide. The ID NOW COVID-19 assay is a simple, user-friendly, rapid molecular biology test based on nicking and extension amplification reaction (NEAR). Objectives : The aim of this study was to evaluate the ID NOW COVID-19 assay when used as a point-of-care test (POCT) in our Emergency Department (ED). Type of study : This prospective study enrolled 395 consecutive patients; paired nasopharyngeal swabs were collected from each study participant. The first swab was tested with the ID NOW COVID-19 assay at the point-of-care by ED nurses. The second swab was diluted in viral transport medium (VTM) and sent to the clinical microbiology department for analysis by both the RT-PCR Simplexa test COVID-19 Direct assay as the study reference method, and the ID NOW COVID-19 assay performed in the laboratory. Results : Nasopharyngeal swabs directly tested with the ID NOW COVID-19 assay yielded a sensitivity, specificity, PPV and NPV of 98.0%, 97.5%, 96.2% and 98.7%, respectively, in comparison with the RT-PCR study reference assay. When the ID NOW COVID-19 assay was performed in the laboratory using the VTM samples, the sensitivity decreased to 62.5% and the NPV to 79.7%. Three false negative test results were reported with the ID NOW COVID-19 assay when performed using undiluted swabs directly in the ED; these results were obtained from patients with elevated CT values (>30). Conclusion : We demonstrated that the ID NOW COVID-19 assay, performed as a point of care test in the ED using dry swabs, provides a rapid and reliable alternative to laboratory-based RT-PCR methods

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date