Selected article for: "real time and similar sensitivity"

Author: Surabattula, Rambabu; Vejandla, Manju Pradeep; Mallepaddi, Prudhvi Chand; Faulstich, Konrad; Polavarapu, Rathnagiri
Title: Simple, rapid, inexpensive platform for the diagnosis of malaria by loop mediated isothermal amplification (LAMP)
  • Cord-id: d43djlyt
  • Document date: 2013_4_4
  • ID: d43djlyt
    Snippet: We attempted to improve the loop-mediated isothermal amplification (LAMP) method for malaria diagnosis by using a simple DNA extraction procedure, and a portable device performing both the amplification and detection of LAMP in one platform. Additionally, the device served as a heating block for the DNA preparation. We refer this method as LAMP-Tube scanner, and evaluated using 209 microscopically positive malaria samples and compared them to RDTs and LAMP-Thermocycler. Two most common human inf
    Document: We attempted to improve the loop-mediated isothermal amplification (LAMP) method for malaria diagnosis by using a simple DNA extraction procedure, and a portable device performing both the amplification and detection of LAMP in one platform. Additionally, the device served as a heating block for the DNA preparation. We refer this method as LAMP-Tube scanner, and evaluated using 209 microscopically positive malaria samples and compared them to RDTs and LAMP-Thermocycler. Two most common human infecting Plasmodium species were detected. The LAMP-Tube scanner method is found to be simple and allowed real-time detection of DNA amplification. The time to amplification varied but was closely less than 60 min. Sensitivity and specificity of LAMP-Tube scanner in detecting Plasmodium falciparum were 95% and 93.3%, compared to microscopy and 98.3% and 100% respectively, compared to standard LAMP-Thermocycler. In addition, it showed a detection limit of 10 and 40 copies of the parasitemia for Plasmodium vivax and P. falciparum. Accordingly, in comparison to the results obtained by microscopy, the LAMP-Tube scanner had a less divergence in sensitivity and specificity, and yielded results similar to those of LAMP-Thermocycler. This method has the great potential as a field usable molecular tool for the diagnosis of malaria and is an alternative to conventional PCR-based diagnostic methods for field use.

    Search related documents:
    Co phrase search for related documents
    • active surveillance and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acute respiratory syndrome and add feature: 1
    • acute respiratory syndrome and additional time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21
    • acute respiratory syndrome and long incubation time: 1, 2, 3, 4, 5, 6
    • acute respiratory syndrome and low template: 1
    • acute respiratory syndrome and lyophilized format: 1