Author: Aya, Hollmann D; Ster, Irina Chis; Fletcher, Nick; Grounds, R Michael; Rhodes, Andrew; Cecconi, Maurizio
Title: Pharmacodynamic Analysis of a Fluid Challenge. Cord-id: x8xb9zyf Document date: 2016_1_1
ID: x8xb9zyf
Snippet: OBJECTIVE This study aims to describe the pharmacodynamics of a fluid challenge over a 10-minute period in postoperative patients. DESIGN Prospective observational study. SETTING General and cardiothoracic ICU, tertiary hospital. PATIENTS Twenty-six postoperative patients. INTERVENTION Two hundred and fifty-milliliter fluid challenge performed over 5 minutes. Data were recorded over 10 minutes after the end of fluid infusion MEASUREMENTS AND MAIN RESULTS Cardiac output was measured with a calibr
Document: OBJECTIVE This study aims to describe the pharmacodynamics of a fluid challenge over a 10-minute period in postoperative patients. DESIGN Prospective observational study. SETTING General and cardiothoracic ICU, tertiary hospital. PATIENTS Twenty-six postoperative patients. INTERVENTION Two hundred and fifty-milliliter fluid challenge performed over 5 minutes. Data were recorded over 10 minutes after the end of fluid infusion MEASUREMENTS AND MAIN RESULTS Cardiac output was measured with a calibrated LiDCOplus (LiDCO, Cambridge, United Kingdom) and Navigator (Applied Physiology, Sydney, Australia) to obtain the Pmsf analogue (Pmsa). Pharmacodynamics outcomes were modeled using a Bayesian inferential approach and Markov chain Monte Carlo estimation methods. Parameter estimates were summarized as the means of their posterior distributions, and their uncertainty was assessed by the 95% credible intervals. Bayesian probabilities for groups' effect were also derived. The predicted maximal effect on cardiac output was observed at 1.2 minutes (95% credible interval, -0.6 to 2.8 min) in responders. The probability that the estimated area under the curve of central venous pressure was smaller in nonresponders was 0.12. (estimated difference, -4.91 mm Hg·min [95% credible interval, -13.45 to 3.3 mm Hg min]). After 10 minutes, there is no evidence of a difference between groups for any hemodynamic variable. CONCLUSIONS The maximal change in cardiac output should be assessed 1 minute after the end of the fluid infusion. The global effect of the fluid challenge on central venous pressure is greater in nonresponders, but not the change observed 10 minutes after the fluid infusion. The effect of a fluid challenge on hemodynamics is dissipated in 10 minutes similarly in both groups.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date