Author: Kim, Hyeong Rae; An, Sanggwon; Hwang, Jungho
Title: An integrated system of air sampling and simultaneous enrichment for rapid biosensing of airborne coronavirus and influenza virus Cord-id: s11obc7w Document date: 2020_9_26
ID: s11obc7w
Snippet: Point-of-care risk assessment (PCRA) for airborne viruses requires a system that can enrich low-concentration airborne viruses dispersed in field environments into a small volume of liquid. In this study, airborne virus particles were collected to a degree above the limit of detection (LOD) for a real-time quantitative reverse transcription polymerase chain reaction (qRT-PCR). This study employed an electrostatic air sampler to capture aerosolized test viruses (human coronavirus 229E (HCoV-229E)
Document: Point-of-care risk assessment (PCRA) for airborne viruses requires a system that can enrich low-concentration airborne viruses dispersed in field environments into a small volume of liquid. In this study, airborne virus particles were collected to a degree above the limit of detection (LOD) for a real-time quantitative reverse transcription polymerase chain reaction (qRT-PCR). This study employed an electrostatic air sampler to capture aerosolized test viruses (human coronavirus 229E (HCoV-229E), influenza A virus subtype H1N1 (A/H1N1), and influenza A virus subtype H3N2 (A/H3N2)) in a continuously flowing liquid (aerosol-to-hydrosol (ATH) enrichment) and a concanavalin A (ConA)-coated magnetic particles (CMPs)-installed fluidic channel for simultaneous hydrosol-to-hydrosol (HTH) enrichment. The air sampler's ATH enrichment capacity (EC) was evaluated using the aerosol counting method. In contrast, the HTH EC for the ATH-collected sample was evaluated using transmission-electron-microscopy (TEM)-based image analysis and real-time qRT-PCR assay. For example, the ATH EC for HCoV-229E was up to 67,000, resulting in a viral concentration of 0.08 PFU/mL (in a liquid sample) for a viral epidemic scenario of 1.2 PFU/m(3) (in air). The real-time qRT-PCR assay result for this liquid sample was “non-detectable†however, subsequent HTH enrichment for 10 min caused the “non-detectable†sample to become “detectable†(cycle threshold (CT) value of 33.8 ± 0.06).
Search related documents:
Co phrase search for related documents- acute sars cov respiratory syndrome coronavirus and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acute sars cov respiratory syndrome coronavirus and low concentration: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acute sars cov respiratory syndrome coronavirus and magnetic particle: 1, 2, 3, 4, 5
- lod detection limit and low concentration: 1, 2, 3, 4, 5
Co phrase search for related documents, hyperlinks ordered by date