Author: Kuo, Chia-Cheng; Chang, Hsiao-Huang; Hsing, Chung-Hsi; Hii, Hiong-Ping; Wu, Nan-Chun; Hsu, Chin-Ming; Chen, Chun-I; Cheng, Bor-Chih
Title: Robotic mitral valve replacements with bioprosthetic valves in 52 patients: experience from a tertiary referral hospital. Cord-id: ggbmsk6h Document date: 2018_1_1
ID: ggbmsk6h
Snippet: OBJECTIVES Robotic mitral valve replacement (MVR) emerged in the late 1990s as an alternative approach to conventional sternotomy. With the increased use of bioprosthetic valves worldwide and strong patient desire for minimally invasive procedures, the safety and feasibility of robotic MVRs with bioprosthetic valves require investigation. METHODS Between January 2013 and May 2017, 52 consecutive patients underwent robotic MVRs using the da Vinci Si surgical system (Intuitive Surgical Inc., Sunny
Document: OBJECTIVES Robotic mitral valve replacement (MVR) emerged in the late 1990s as an alternative approach to conventional sternotomy. With the increased use of bioprosthetic valves worldwide and strong patient desire for minimally invasive procedures, the safety and feasibility of robotic MVRs with bioprosthetic valves require investigation. METHODS Between January 2013 and May 2017, 52 consecutive patients underwent robotic MVRs using the da Vinci Si surgical system (Intuitive Surgical Inc., Sunnyvale, CA, USA). Their mean age was 55.1 ± 13.8 years, and mean EuroSCORE II was 2.25% ± 1.25%. Among the enrolled patients, 32 (61.5%) patients presented with preoperative atrial fibrillation, 6 (11.5%) patients had experienced embolic stroke and 5 (9.6%) patients had undergone previous cardiac surgery. The operations were performed using cardiopulmonary bypass (CPB) under an arrested heart status. RESULTS Five porcine valves and 47 bovine valves were implanted. A total of 38 (73.1%) patients received concomitant cardiac procedures, including 26 Cox-maze IV procedures, 12 tricuspid valve repairs and 5 atrial septal defect repairs. The mean aortic cross-clamp and CPB times were 141.3 ± 34.3 min and 217.1 ± 42.0 min, respectively. There was no operative mortality. During the mean follow-up of 29 ± 15 months, no prosthesis degeneration was noted. The average left atrial dimension exhibited a significant decrease from 51.4 ± 11.5 mm to 42.6 ± 10.1 mm. CONCLUSIONS Robotic MVR with bioprosthetic valves is safe, feasible and reproducible. Mid-term results are encouraging. Both aortic cross-clamp and CPB times can be improved with experience.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date