Author: Purohit, Kiran; Kesarwani, Abhishek; Kisku, Dakshina Ranjan; Dalui, Mamata
Title: COVID-19 Detection on Chest X-Ray and CT Scan Images Using Multi-image Augmented Deep Learning Model Cord-id: dtnf81lx Document date: 2020_10_19
ID: dtnf81lx
Snippet: COVID-19 is posed as very infectious and deadly pneumonia type disease until recent time. Despite having lengthy testing time, RT-PCR is a proven testing methodology to detect coronavirus infection. Sometimes, it might give more false positive and false negative results than the desired rates. Therefore, to assist the traditional RT-PCR methodology for accurate clinical diagnosis, COVID-19 screening can be adopted with X-Ray and CT scan images of lung of an individual. This image based diagnosis
Document: COVID-19 is posed as very infectious and deadly pneumonia type disease until recent time. Despite having lengthy testing time, RT-PCR is a proven testing methodology to detect coronavirus infection. Sometimes, it might give more false positive and false negative results than the desired rates. Therefore, to assist the traditional RT-PCR methodology for accurate clinical diagnosis, COVID-19 screening can be adopted with X-Ray and CT scan images of lung of an individual. This image based diagnosis will bring radical change in detecting coronavirus infection in human body with ease and having zero or near to zero false positives and false negatives rates. This paper reports a convolutional neural network (CNN) based multi-image augmentation technique for detecting COVID-19 in chest X-Ray and chest CT scan images of coronavirus suspected individuals. Multi-image augmentation makes use of discontinuity information obtained in the filtered images for increasing the number of effective examples for training the CNN model. With this approach, the proposed model exhibits higher classification accuracy around 95.38% and 98.97% for CT scan and X-Ray images respectively. CT scan images with multi-image augmentation achieves sensitivity of 94.78% and specificity of 95.98%, whereas X-Ray images with multi-image augmentation achieves sensitivity of 99.07% and specificity of 98.88%. Evaluation has been done on publicly available databases containing both chest X-Ray and CT scan images and the experimental results are also compared with ResNet-50 and VGG-16 models.
Search related documents:
Co phrase search for related documents- accuracy precision and activation function: 1, 2, 3
- accuracy precision and activation function relu: 1, 2
- accuracy precision and loss classification accuracy: 1
- accuracy precision and loss function: 1, 2, 3, 4, 5, 6, 7, 8, 9
- activation function and loss function: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- activation function relu and loss function: 1
- activation function sigmoid and loss function: 1, 2
- loss function and low level feature: 1
Co phrase search for related documents, hyperlinks ordered by date