Selected article for: "critically ill patient and respiratory system"

Author: Ryu, Jeong-Am; Choi, Kyoungjin; Yang, Jeong Hoon; Lee, Dae-Sang; Suh, Gee Young; Jeon, Kyeongman; Cho, Joongbum; Chung, Chi Ryang; Sohn, Insuk; Kim, Kiyoun; Park, Chi-Min
Title: Clinical usefulness of capnographic monitoring when inserting a feeding tube in critically ill patients: retrospective cohort study.
  • Cord-id: zk8v568f
  • Document date: 2016_1_1
  • ID: zk8v568f
    Snippet: BACKGROUND It is not rare for a small-bore feeding tube to be inserted incorrectly into the respiratory system in critically ill patients. Thus, monitoring is necessary to prevent respiratory malplacement of the tube. We investigated the utility of capnographic monitoring to prevent respiratory complications due to feeding tube mispositioning in critically ill patients. METHODS This study was a pre and post-interventional study, including 445 feeding tube placements events studied retrospectivel
    Document: BACKGROUND It is not rare for a small-bore feeding tube to be inserted incorrectly into the respiratory system in critically ill patients. Thus, monitoring is necessary to prevent respiratory malplacement of the tube. We investigated the utility of capnographic monitoring to prevent respiratory complications due to feeding tube mispositioning in critically ill patients. METHODS This study was a pre and post-interventional study, including 445 feeding tube placements events studied retrospectively in the medical and surgical intensive care units of the Samsung Medical Center. We compared outcomes between time periods before and after capnographic monitoring and documented any respiratory complications. RESULTS Feeding tubes were inserted in 275 cases without capnographic monitoring. Capnographic monitoring was performed in 170 cases. Sixteen patients (4%) had respiratory complications of all tube placements. Feeding tube was inserted into the trachea in 11 (2%) patients and for a pneumothorax in five (1%) patients. Fourteen cases of respiratory complications were detected in the control group (14/275, 5%, 10 tracheal insertions and four pneumothoraxes). Two respiratory complications were detected in the capnographic monitoring group (2/170, 1%, one tracheal insertion and one pneumothorax). Respiratory complications were detected less frequently in the capnographic monitoring group than that in the control group (P = 0.035). CONCLUSIONS Capnographic monitoring is simple, easy to learn, and may be useful to prevent respiratory complications when placing a feeding tube in a critically ill patient.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date