Selected article for: "antibody detection and negative rate"

Author: Li, Jianyong; Lin, Rui; Yang, Yi; Zhao, Rongtao; Song, Shiping; Zhou, Yi; Shi, Jiye; Wang, Lihua; Song, Hongbin; Hao, Rongzhang
Title: Multichannel Immunosensor Platform for the Rapid Detection of SARS-CoV-2 and Influenza A(H1N1) Virus
  • Cord-id: xwsq752f
  • Document date: 2021_5_10
  • ID: xwsq752f
    Snippet: [Image: see text] The coronavirus disease 2019 (COVID-19) can present a similar syndrome to an influenza infection, which may complicate diagnosis and clinical management of these two important respiratory infectious diseases, especially during the peak season of influenza. A rapid and convenient point-of-care test (POCT) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza virus is of great importance for prompt and efficient control of these respiratory epidemics. Her
    Document: [Image: see text] The coronavirus disease 2019 (COVID-19) can present a similar syndrome to an influenza infection, which may complicate diagnosis and clinical management of these two important respiratory infectious diseases, especially during the peak season of influenza. A rapid and convenient point-of-care test (POCT) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza virus is of great importance for prompt and efficient control of these respiratory epidemics. Herein, a multichannel electrochemical immunoassay (MEIA) platform was developed based on a disposable screen-printed carbon electrode (SPCE) array for the on-site detection of SARS-CoV-2 and A(H1N1). The developed MEIA was constructed with eight channels and allowed rapid detection on a single array. On the SPCE surface, monoclonal antibodies against influenza A(H1N1) hemagglutinin (HA) protein or SARS-CoV-2 spike protein were coated to capture the target antigens, which then interacted with a horseradish peroxidase (HRP)-labeled detection antibody to form an immuno-sandwich complex. The results showed that the MEIA exhibited a broader linear range than ELISA and comparable sensitivity for A(H1N1) HA and SARS-CoV-2 spike protein. The detection results on 79 clinical samples for A(H1N1) suggested that the proposed MEIA platform showed comparable results with ELISA in sensitivity (with a positive rate of 100% for positive samples) but higher specificity, with a false-positive rate of 5.4% for negative samples versus that of 40.5% with ELISA. Thus, it offers great potential for the on-the-spot differential diagnosis of infected patients, which would significantly benefit the efficient control and prevent the spread of these infectious diseases in communities or resource-limited regions in the future.

    Search related documents:
    Co phrase search for related documents
    • accuracy high sensitivity and acid testing: 1, 2, 3
    • accuracy specificity and acid detection: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • accuracy specificity and acid testing: 1, 2, 3, 4, 5, 6
    • accuracy specificity and live virus: 1
    • accuracy specificity and long impact: 1
    • acid detection and live virus: 1, 2, 3, 4
    • acid testing and live virus: 1
    • acid testing and long impact: 1