Selected article for: "ELISA kit and IgG elisa"

Author: Edouard, Sophie; Jaafar, Rita; Orain, Nicolas; Parola, Philippe; Colson, Philippe; La Scola, Bernard; Fournier, Pierre-Edouard; Raoult, Didier; Drancourt, Michel
Title: Automated Western immunoblotting detection of anti-SARS-CoV-2 serum antibodies
  • Cord-id: hyep9yfx
  • Document date: 2021_3_3
  • ID: hyep9yfx
    Snippet: ELISA and chemiluminescence serological assays for COVID-19 are currently incorporating only one or two SARS-CoV-2 antigens. We developed an automated Western immunoblotting as a complementary serologic assay for COVID-19. The Jess(TM) Simple Western system, an automated capillary-based assay, was used, incorporating an inactivated SARS-CoV-2 lineage 20a strain as the source of antigen, and total immunoglobulins (IgG, IgM, IgA) detection. In total, 602 sera were tested including 223 from RT-PCR-
    Document: ELISA and chemiluminescence serological assays for COVID-19 are currently incorporating only one or two SARS-CoV-2 antigens. We developed an automated Western immunoblotting as a complementary serologic assay for COVID-19. The Jess(TM) Simple Western system, an automated capillary-based assay, was used, incorporating an inactivated SARS-CoV-2 lineage 20a strain as the source of antigen, and total immunoglobulins (IgG, IgM, IgA) detection. In total, 602 sera were tested including 223 from RT-PCR-confirmed COVID-19 patients, 76 from patients diagnosed with seasonal HCoVs and 303 from coronavirus-negative control sera. We also compared this assay with the EUROIMMUN® SARS-CoV-2 IgG ELISA kit. Among 223 sera obtained from RT-PCR-confirmed COVID-19 patients, 180/223 (81%) exhibited reactivity against the nucleocapsid and 70/223 (31%) against the spike protein. Nucleocapsid reactivity was further detected in 9/76 (14%) samples collected from patients diagnosed with seasonal HCoVs and in 15/303 (5%) coronavirus-negative control samples. In the subset of sera collected more than 2 weeks after the onset of symptoms, the sensitivity was 94% and the specificity 93%, the latter value probably reflecting cross-reactivity of SARS-CoV-2 with other coronaviruses. The automated Western immunoblotting presented a substantial agreement (90%) with the compared ELISA (Cohen’s Kappa=0.64). Automated Western immunoblotting may be used as a second line test to monitor exposure of people to HCoVs including SARS-CoV-2. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10096-021-04203-8.

    Search related documents: