Selected article for: "cross reaction and detection sensitivity"

Author: Matushek, Scott M.; Beavis, Kathleen G.; Abeleda, Ana; Bethel, Cindy; Hunt, Carlissa; Gillen, Stephanie; Moran, Angelica; Tesic, Vera
Title: Evaluation of the EUROIMMUN Anti-SARS-CoV-2 ELISA Assay for detection of IgA and IgG antibodies
  • Cord-id: jzpwo5un
  • Document date: 2020_5_13
  • ID: jzpwo5un
    Snippet: As the Coronavirus 2019 (COVID-19) pandemic evolves, the development of immunoassays to help determine exposure and potentially predict immunity has become a pressing priority. In this report we present the performance of the EUROIMMUN enzyme-linked immunosorbent assay (ELISA) for semi-quantitative detection of IgA and IgG antibodies in serum and plasma samples using recombinant S1 domain of the SARS-CoV-2 spike protein as antigen. Specimens from patients, with and without COVID-19 infection, we
    Document: As the Coronavirus 2019 (COVID-19) pandemic evolves, the development of immunoassays to help determine exposure and potentially predict immunity has become a pressing priority. In this report we present the performance of the EUROIMMUN enzyme-linked immunosorbent assay (ELISA) for semi-quantitative detection of IgA and IgG antibodies in serum and plasma samples using recombinant S1 domain of the SARS-CoV-2 spike protein as antigen. Specimens from patients, with and without COVID-19 infection, were tested at the University of Chicago Clinical Microbiology and Immunology Laboratory. Of 57 samples from COVID-19 PCR-negative patients, including 28 samples positive for common human coronavirus strains, 53 tested negative and 4 tested positive for IgA (93.0% agreement) while 56 tested negative and 1 tested positive for IgG (98.2% agreement). For COVID-19 PCR-positive patients, 29 of 30 (96.7%) samples collected ≥3 days after positive PCR were positive for IgA, and 28 of 28 samples collected ≥4 days after positive PCR were positive for IgG. The EUROIMMUN Anti-SARS-CoV-2 ELISA Assay demonstrates excellent sensitivity for detection of IgA and IgG antibodies from samples collected ≥3 days and ≥4 days, respectively, after COVID-19 diagnosis by PCR. This assay did not demonstrate cross reaction in any of the 28 samples from patients with common human coronaviruses, including types HKU1, NL63, CV229E, and OC43.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date