Selected article for: "expiratory volume and FEV1 fvc"

Author: Wijbenga, Nynke; Hoek, Rogier A. S.; Mathot, Bas J.; Seghers, Leonard; van Weezel, Jan J.; den Ouden, José; Wijsenbeek, Marlies S.; Aerts, Joachim G. J. V.; Hellemons, Merel E.; Moor, Catharina C.
Title: Evaluation of a Home Monitoring Application for Follow Up after Lung Transplantation—A Pilot Study
  • Cord-id: elef73n7
  • Document date: 2020_11_21
  • ID: elef73n7
    Snippet: Home spirometry after lung transplantation is common practice, to monitor graft function. However, there is little experience with online home monitoring applications with direct data transfer to the hospital. We evaluated the feasibility and patient experiences with a new online home monitoring application, integrated with a Bluetooth-enabled spirometer and real-time data transfer. Consecutive lung transplant recipients were asked to evaluate this home monitoring application for three months in
    Document: Home spirometry after lung transplantation is common practice, to monitor graft function. However, there is little experience with online home monitoring applications with direct data transfer to the hospital. We evaluated the feasibility and patient experiences with a new online home monitoring application, integrated with a Bluetooth-enabled spirometer and real-time data transfer. Consecutive lung transplant recipients were asked to evaluate this home monitoring application for three months in a pilot study. Home spirometry measurements were compared with in-hospital lung function tests (the forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC)) at the end of the study. Ten patients participated. The home and hospital spirometry measurements showed a high correlation, for both the FEV1 (r = 0.99, p < 0.01) and FVC (r = 0.99, p < 0.01). The adherence and patient satisfaction were high, and the patients preferred the home monitoring application over the current home spirometer, with a difference of 1.4 ± 1.5 points on a scale from 0 to 10 (p = 0.02). Online home monitoring with direct data transfer is feasible and reliable after lung transplantation and results in high patient satisfaction. Whether the implementation of online home monitoring enables the earlier detection of lung function decline and improves patient and graft outcomes will be the subject of future research.

    Search related documents:
    Co phrase search for related documents
    • acute rejection and long follow: 1, 2, 3
    • acute rejection and lung disease: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
    • acute rejection and lung function: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    • adherence improve and long follow: 1, 2
    • adherence improve and long term adherence: 1, 2, 3, 4, 5, 6, 7
    • adherence improve and long term adherence improve: 1, 2, 3, 4
    • adherence improve and lung disease: 1
    • adherence improve and lung function: 1, 2
    • adherence monitoring and long follow: 1
    • adherence monitoring and long term adherence: 1, 2, 3, 4, 5
    • adherence monitoring and lung disease: 1
    • adherence monitoring and lung function: 1
    • adherence monitoring and lung function change: 1
    • adherence non and admission prior: 1
    • adherence non and long follow: 1, 2, 3
    • adherence non and long term adherence: 1, 2, 3
    • adherence non and long term adherence improve: 1
    • adherence non and lung function: 1
    • admission prior and lung function: 1