Selected article for: "PCR kit and RNA dna"

Author: Wanda J. Lyon; Zachary K. Smith; Brian Grier; James Baldwin; Clarise R. Starr
Title: Evaluating an Upper Respiratory Disease Panel on the Portable MinION Sequencer
  • Document date: 2018_10_5
  • ID: 3begdfx2_5
    Snippet: Standard targeted PCR was done per using primers listed in Table 1 and the SuperScript III OneStep RT-PCR system (Thermo Fisher Scientific) per the manufacturer's instructions. Briefly, 10 ng of DNA-free RNA or RNA-free DNA was used for each 50-μL reaction. All PCR reactions were accomplished with 1.0 ul of each primer at 10 uM. RT-PCR thermocycling parameters were as follows: 30 minutes at 50°C, 2 minutes at 95°C, and then 35 cycles of 30 sec.....
    Document: Standard targeted PCR was done per using primers listed in Table 1 and the SuperScript III OneStep RT-PCR system (Thermo Fisher Scientific) per the manufacturer's instructions. Briefly, 10 ng of DNA-free RNA or RNA-free DNA was used for each 50-μL reaction. All PCR reactions were accomplished with 1.0 ul of each primer at 10 uM. RT-PCR thermocycling parameters were as follows: 30 minutes at 50°C, 2 minutes at 95°C, and then 35 cycles of 30 seconds at 95°C, 30 seconds at 52°C, and 75 seconds at 68°C, followed with a final extension at 68°C for 5 minutes. PCR thermocycling was accomplished with AccuStartII PCR Supermix of the DNA fragments was completed using barcoding kit (EXP-PBC001). Libraries kit used for each of the sequencing libraries are shown in Table 2 and 3, as well as the amount of starting material and flow cells type. Library preparations were done as described by the manufacturer and were quantified using a Qubit 3.0 fluorometer (Life Technologies).

    Search related documents:
    Co phrase search for related documents
    • barcoding kit and library kit: 1, 2
    • barcoding kit and library preparation: 1, 2, 3, 4
    • dna fragment and final extension: 1, 2, 3
    • dna fragment and library kit: 1
    • dna fragment and library preparation: 1, 2, 3
    • dna fragment and PCR reaction: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    • final extension and library preparation: 1
    • final extension and PCR reaction: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    • flow cell and library kit: 1, 2, 3, 4
    • flow cell and library preparation: 1, 2, 3
    • flow cell and Life Technologies Qubit fluorometer: 1
    • flow cell and manufacturer instruction: 1
    • flow cell and PCR reaction: 1, 2, 3, 4, 5, 6, 7, 8
    • library kit and PCR reaction: 1, 2
    • library preparation and Life Technologies Qubit fluorometer: 1
    • library preparation and manufacturer instruction: 1
    • library preparation and PCR reaction: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • Life Technologies Qubit fluorometer and manufacturer instruction: 1