Author: Faverio, Paola; Ornaghi, Sara; Stainer, Anna; Invernizzi, Francesca; Borelli, Mara; Brunetti, Federica; La Milia, Laura; Paolini, Valentina; Rona, Roberto; Foti, Giuseppe; Luppi, Fabrizio; Vergani, Patrizia; Pesci, Alberto
Title: Feasibility of CPAP application and variables related to worsening of respiratory failure in pregnant women with SARS-CoV-2 pneumonia: Experience of a tertiary care centre Cord-id: ktzbzbvr Document date: 2021_10_19
ID: ktzbzbvr
Snippet: Continuous positive airway pressure (CPAP) has been successfully applied to patients with COVID-19 to prevent endotracheal intubation. However, experience of CPAP application in pregnant women with acute respiratory failure (ARF) due to SARS-CoV-2 pneumonia is scarce. This study aimed to describe the natural history and outcome of ARF in a cohort of pregnant women with SARS-CoV-2 pneumonia, focusing on the feasibility of helmet CPAP (h-CPAP) application and the variables related to ARF worsening
Document: Continuous positive airway pressure (CPAP) has been successfully applied to patients with COVID-19 to prevent endotracheal intubation. However, experience of CPAP application in pregnant women with acute respiratory failure (ARF) due to SARS-CoV-2 pneumonia is scarce. This study aimed to describe the natural history and outcome of ARF in a cohort of pregnant women with SARS-CoV-2 pneumonia, focusing on the feasibility of helmet CPAP (h-CPAP) application and the variables related to ARF worsening. A retrospective, observational study enrolling 41 consecutive pregnant women hospitalised for SARS-CoV-2 pneumonia in a tertiary care center between March 2020 and March 2021. h-CPAP was applied if arterial partial pressure of oxygen to fraction of inspired oxygen ratio (PaO(2)/FiO(2)) was inferior to 200 and/or patients had respiratory distress despite adequate oxygen supplementation. Characteristics of patients requiring h-CPAP vs those in room air or oxygen only were compared. Twenty-seven (66%) patients showed hypoxemic ARF requiring oxygen supplementation and h-CPAP was needed in 10 cases (24%). PaO(2)/FiO(2) was significantly improved during h-CPAP application. The device was well-tolerated in all cases with no adverse events. Higher serum C reactive protein and more extensive (≥3 lobes) involvement at chest X-ray upon admission were observed in the h-CPAP group. Assessment of temporal distribution of cases showed a substantially increased rate of CPAP requirement during the third pandemic wave (January-March 2021). In conclusion, h-CPAP was feasible, safe, well-tolerated and improved oxygenation in pregnant women with moderate-to-severe ARF due to SARS-CoV-2 pneumonia. Moderate-to-severe ARF was more frequently observed during the third pandemic wave.
Search related documents:
Co phrase search for related documents- abg clinical and acute respiratory distress syndrome: 1
- abg clinical and acute respiratory distress syndrome pneumonia: 1
- abg clinical and acute respiratory failure: 1
- abg clinical and lung involvement: 1
- acute respiratory distress syndrome and low molecular weight heparin: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20
- acute respiratory distress syndrome and lung involvement: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acute respiratory distress syndrome pneumonia and low molecular weight heparin: 1, 2
- acute respiratory distress syndrome pneumonia and lung involvement: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- acute respiratory failure and low molecular weight heparin: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- acute respiratory failure and lung involvement: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
Co phrase search for related documents, hyperlinks ordered by date