Selected article for: "acid nucleic and acute stage"

Author: Xiong, Huiwen; Ye, Xin; Li, Yang; Qi, Jun; Fang, Xueen; Kong, Jilie
Title: Efficient Microfluidic-Based Air Sampling/Monitoring Platform for Detection of Aerosol SARS-CoV-2 On-site.
  • Cord-id: dq3m9ygq
  • Document date: 2021_2_26
  • ID: dq3m9ygq
    Snippet: Airborne pathogens have been considered as highly infectious and transmittable between humans. With the pandemic outbreak of the coronavirus disease 2019 (COVID-19), an on-site diagnostic system-integrated airborne pathogen-monitoring machine is recommended by experts for preventing and controlling the early stage β-coronavirus severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spread. In this work, a small-volume rotating microfluidic fluorescence chip-integrated aerosol SARS-CoV-2 s
    Document: Airborne pathogens have been considered as highly infectious and transmittable between humans. With the pandemic outbreak of the coronavirus disease 2019 (COVID-19), an on-site diagnostic system-integrated airborne pathogen-monitoring machine is recommended by experts for preventing and controlling the early stage β-coronavirus severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spread. In this work, a small-volume rotating microfluidic fluorescence chip-integrated aerosol SARS-CoV-2 sampling system was constructed to satisfy the demand for rapid on-site sample collection and detection of SARS-CoV-2. The rotating microfluidic fluorescence system with small volume has very high sensitivity in the detection of SARS-CoV-2 (detection limit of 10 copies/μL with the shortest Ct value of 15 min), which is comparable to reverse transcription polymerase chain reaction (RT-PCR). The precision variation coefficients within/between batches are very low [coefficient of variation (CV) % ≤ 5.0%]. Our work has passed the comprehensive inspection of the microfluidic chip performance by the Shanghai Medical Device Testing Institute [National Medical Inspection (Design) no. 4408] and successfully tested 115 clinical samples. The integrated system exhibits 100% specificity, high sensitivity (10 copies/μL), and good precision (CV % ≤ 5.0%) in the rapid detection of SARS-CoV-2, thus realizing rapid monitoring and diagnostics of SARS-CoV-2 nucleic acid on-site.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date