Selected article for: "acute respiratory syndrome and additional pcr"

Author: Yokoyama, Rin; Kurano, Makoto; Morita, Yoshifumi; Shimura, Takuya; Nakano, Yuki; Qian, Chungen; Xia, Fuzhen; He, Fan; Kishi, Yoshiro; Okada, Jun; Yoshikawa, Naoyuki; Nagura, Yutaka; Okazaki, Hitoshi; Moriya, Kyoji; Seto, Yasuyuki; Kodama, Tatsuhiko; Yatomi, Yutaka
Title: Validation of a new automated chemiluminescent anti-SARS-CoV-2 IgM and IgG antibody assay system detecting both N and S proteins in Japan
  • Cord-id: gtl8k0ki
  • Document date: 2021_3_4
  • ID: gtl8k0ki
    Snippet: PCR methods are presently the standard for the diagnosis of Coronavirus disease 2019 (COVID-19), but additional methodologies are needed to complement PCR methods, which have some limitations. Here, we validated and investigated the usefulness of measuring serum antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using the iFlash3000 CLIA analyzer. We measured IgM and IgG titers against SARS-CoV-2 in sera collected from 26 PCR-positive COVID-19 patients, 53 COVID-19-s
    Document: PCR methods are presently the standard for the diagnosis of Coronavirus disease 2019 (COVID-19), but additional methodologies are needed to complement PCR methods, which have some limitations. Here, we validated and investigated the usefulness of measuring serum antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using the iFlash3000 CLIA analyzer. We measured IgM and IgG titers against SARS-CoV-2 in sera collected from 26 PCR-positive COVID-19 patients, 53 COVID-19-suspected but PCR-negative patients, and 20 and 100 randomly selected non-COVID-19 patients who visited our hospital in 2020 and 2017, respectively. The repeatability and within-laboratory precision were obviously good in validations, following to the CLSI document EP15-A3. Linearity was also considered good between 0.6 AU/mL and 112.7 AU/mL for SARS-CoV-2 IgM and between 3.2 AU/mL and 55.3 AU/mL for SARS-CoV-2 IgG, while the linearity curves plateaued above the upper measurement range. We also confirmed that the seroconversion and no-antibody titers were over the cutoff values in all 100 serum samples collected in 2017. These results indicate that this measurement system successfully detects SARS-CoV-2 IgM/IgG. We observed four false-positive cases in the IgM assay and no false-positive cases in the IgG assay when 111 serum samples known to contain autoantibodies were evaluated. The concordance rates of the antibody test with the PCR test were 98.1% for SARS-CoV-2 IgM and 100% for IgG among PCR-negative cases and 30.8% for SARS-CoV-2 IgM and 73.1% for SARS-CoV-2 IgG among PCR-positive cases. In conclusion, the performance of this new automated method for detecting antibody against both N and S proteins of SARS-CoV-2 is sufficient for use in laboratory testing.

    Search related documents:
    Co phrase search for related documents
    • acute respiratory infection syndrome and lod detection limit: 1, 2, 3
    • acute respiratory infection syndrome and lymphopenia cough: 1
    • acute respiratory infection syndrome and lymphopenia cough fever: 1
    • lob blank limit and lod detection limit: 1, 2, 3, 4
    • lob blank limit and loq quantitation: 1
    • lob blank limit and loq quantitation limit: 1
    • lob blank limit and loq quantitation limit lod detection limit: 1
    • lod detection limit and loq quantitation: 1, 2, 3
    • lod detection limit and loq quantitation limit: 1, 2, 3
    • lod detection limit and loq quantitation limit lod detection limit: 1, 2, 3
    • lod detection limit and magnetic bead: 1, 2