Author: Desai, Kanan T.; Alfaro, Karla; Mendoza, Laura; Faron, Matthew; Mesich, Brian; Maza, Mauricio; Dominguez, Rhina; Valenzuela, Adriana; Acosta, Chyntia DÃaz; MartÃnez, Magaly; Felix, Juan C.; Masch, Rachel; Gabrilovich, Sofia; Plump, Michael; Novetsky, Akiva P.; Einstein, Mark H.; Douglas, Nataki C.; Cremer, Miriam; Wentzensen, Nicolas
Title: Multi-site clinical validation of Isothermal Amplification based SARS-COV-2 detection assays using different sampling strategies Cord-id: l2cgx3ll Document date: 2021_7_6
ID: l2cgx3ll
Snippet: BACKGROUND: Isothermal amplification-based tests were developed as rapid, low-cost, and simple alternatives to real-time reverse transcriptase-polymerase chain reaction (RT-PCR) tests for SARS-COV-2 detection. METHODS: Clinical performance of two isothermal amplification-based tests (Atila Biosystems iAMP COVID-19 detection test and OptiGene COVID-19 Direct Plus RT-LAMP test) was compared to clinical RT-PCR assays using different sampling strategies. A total of 1378 participants were tested acro
Document: BACKGROUND: Isothermal amplification-based tests were developed as rapid, low-cost, and simple alternatives to real-time reverse transcriptase-polymerase chain reaction (RT-PCR) tests for SARS-COV-2 detection. METHODS: Clinical performance of two isothermal amplification-based tests (Atila Biosystems iAMP COVID-19 detection test and OptiGene COVID-19 Direct Plus RT-LAMP test) was compared to clinical RT-PCR assays using different sampling strategies. A total of 1378 participants were tested across four study sites. RESULTS: Compared to standard of care RT-PCR testing, the overall sensitivity and specificity of the Atila iAMP test for detection of SARS-CoV-2 were 76.2% and 94.9%, respectively, and increased to 88.8% and 89.5%, respectively, after exclusion of an outlier study site. Sensitivity varied based on the anatomic collected site. Sensitivity for nasopharyngeal was 65.4% (range across study sites:52.8%–79.8%), mid-turbinate 88.2%, saliva 55.1% (range across study sites:42.9%–77.8%) and anterior nares 66.7% (range across study sites:63.6%–76.5%). The specificity for these anatomic collection sites ranged from 96.7% to 100%. Sensitivity improved in symptomatic patients (overall 82.7%) and those with a higher viral load (overall 92.4% for ct≤25). Sensitivity and specificity of the OptiGene Direct Plus RT-LAMP test, conducted at a single study-site, were 25.5% and 100%, respectively. CONCLUSIONS: The Atila iAMP COVID test with mid-turbinate sampling is a rapid, low-cost assay for detecting SARS-COV-2, especially in symptomatic patients and those with a high viral load, and could be used to reduce the risk of SARS-COV-2 transmission in clinical settings. Variation of performance between study sites highlights the need for site-specific clinical validation of these assays before clinical adoption.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date