Selected article for: "compliance rate and pilot study"

Author: Szczapa, Tomasz; Gadzinowski, Janusz; Moczko, Jerzy; Merritt, T Allen
Title: Heliox for mechanically ventilated newborns with bronchopulmonary dysplasia.
  • Cord-id: j9ylhxta
  • Document date: 2014_1_1
  • ID: j9ylhxta
    Snippet: OBJECTIVE We assessed the safety and studied the influence of short-term helium-oxygen (heliox) mechanical ventilation (MV) on respiratory function, gas exchange and oxygenation in infants with bronchopulmonary dysplasia (BPD) or at high risk for BPD. DESIGN A pilot, time-series study. SETTING Neonatal intensive care unit. PATIENTS Infants with severe BPD who required MV. INTERVENTIONS MV with helium-oxygen and air-oxygen mixtures. MAIN OUTCOME MEASURES Respiratory parameters, acid-base balance,
    Document: OBJECTIVE We assessed the safety and studied the influence of short-term helium-oxygen (heliox) mechanical ventilation (MV) on respiratory function, gas exchange and oxygenation in infants with bronchopulmonary dysplasia (BPD) or at high risk for BPD. DESIGN A pilot, time-series study. SETTING Neonatal intensive care unit. PATIENTS Infants with severe BPD who required MV. INTERVENTIONS MV with helium-oxygen and air-oxygen mixtures. MAIN OUTCOME MEASURES Respiratory parameters, acid-base balance, oxygenation and vital signs were recorded at five time points: initially during MV with air-oxygen, after 15 and 60 min of helium-oxygen MV, and 15 and 60 min after return to air-oxygen MV. RESULTS 15 infants with BPD were enrolled. Helium-oxygen MV was well tolerated and was associated with a statistically significant increase in tidal volume, dynamic compliance and peak expiratory flow rate. An improvement in oxygenation and a decrease in fraction of inspired oxygen was also observed. During helium-oxygen MV there was a significant decrease in the oxygenation index and alveolar-arterial oxygen tension difference. The PaO2/fraction of inspired oxygen (FiO2) ratio increased significantly during helium-oxygen ventilation. A decrease in PaCO2 and an increase in pH were also observed during helium-oxygen administration, however this was not statistically significant. After ventilation with helium-oxygen was discontinued, the infants' respiratory function and oxygenation deteriorated and supplemental oxygen requirements increased accordingly. CONCLUSIONS Helium-oxygen MV is safe and resulted in improvement of respiratory function and oxygenation in infants with severe BPD requiring MV.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date