Author: Mohanraj, D.; Whitelegg, A.; Bicknell, K.; Bhole, M.; Webber, C.; Taylor, L.
Title: Comparative assessment of SARS-CoV-2 serology in healthcare workers with Abbott Architect, Roche Elecsys and The Binding site ELISA immunoassays. Cord-id: lahq4sud Document date: 2021_3_24
ID: lahq4sud
Snippet: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology testing is key for assessing seroprevalence and antibody response post-vaccination in immunocompromised patients. Here we performed a comparison between two high-throughput nucleocapsid assays (Abbott SARS-CoV-2 IgG and Roche Elecsys Anti-SARS-CoV-2) and The Binding Site (TBS) anti-Spike IgG/A/M- SARS-CoV-2 ELISA kit. 236 samples were collected across 2 sites, Portsmouth Hospital University NHS Trust (PHU) and The Dudley Group
Document: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology testing is key for assessing seroprevalence and antibody response post-vaccination in immunocompromised patients. Here we performed a comparison between two high-throughput nucleocapsid assays (Abbott SARS-CoV-2 IgG and Roche Elecsys Anti-SARS-CoV-2) and The Binding Site (TBS) anti-Spike IgG/A/M- SARS-CoV-2 ELISA kit. 236 samples were collected across 2 sites, Portsmouth Hospital University NHS Trust (PHU) and The Dudley Group NHS Trust. We derived concordance, agreement and assay performance as well as using receiver operating characteristic (ROC) curves to redefine the assay threshold of the Abbott assay. Result concordance between the Abbott and TBS was 66%. Discrepant samples were analysed using the Roche assay which showed 100% agreement with the TBS assay. In samples analysed >58 days post-PCR, the sensitivity of Abbott and Roche was 100%. In samples analysed >100 days post-PCR the sensitivity of the Abbott assay dropped to 77.2% but remained at 100% for the Roche assay. A redefined Abbott threshold of 0.64 increased the sensitivity to 90% giving results similar to the Roche and TBS assays. In conclusion, this study demonstrated Abbott assay had a lower sensitivity in comparison to TBS and Roche. This study established TBS can be implemented as a viable alternative for SARS-CoV-2 serology testing where high-throughput assays are not available on site. Furthermore, anti-spike assays, such as TBS, could be used to monitor vaccination responses to deduce SARS-CoV-2 population-immunity. Further optimization studies are required to evaluate the performance characteristics of these assays which could facilitate widescale sero-epidemiological surveillance.
Search related documents:
Co phrase search for related documents, hyperlinks ordered by date