Author: Christiansen, Mark; Bartee, Amy; LaLonde, Amy; Jones, Richard E; Katz, Michelle L; Wolpert, Harold; Brazg, Ronald
Title: PERFORMANCE OF AN AUTOMATED INSULIN DELIVERY (AID) SYSTEM: RESULTS OF EARLY PHASE FEASIBILITY STUDIES. Cord-id: iox3ozr1 Document date: 2020_9_17
ID: iox3ozr1
Snippet: BACKGROUND Automated insulin delivery (AID) systems have demonstrated improvements in time-in-range (TIR, blood glucose 70-180 mg/dL) without increasing hypoglycemia. Testing a closed loop system in an inpatient environment with supervised challenges allows for initial evaluation of performance and safety of the system. METHODS Adults with type 1 diabetes (T1D) were enrolled into two similar studies (n=10/study), with 3-day inpatient analysis periods. Participants tested a Lilly hybrid closed lo
Document: BACKGROUND Automated insulin delivery (AID) systems have demonstrated improvements in time-in-range (TIR, blood glucose 70-180 mg/dL) without increasing hypoglycemia. Testing a closed loop system in an inpatient environment with supervised challenges allows for initial evaluation of performance and safety of the system. METHODS Adults with type 1 diabetes (T1D) were enrolled into two similar studies (n=10/study), with 3-day inpatient analysis periods. Participants tested a Lilly hybrid closed loop (HCL) system comprised an investigational insulin pump, insulin lispro, a pump-embedded model predictive control algorithm, a continuous glucose monitor (CGM), and an external, dedicated controller. Each protocol included meal-related and exercise challenges to simulate real-world diabetes self-management errors. Only study staff interacted with the HCL system. Performance was assessed using standard CGM metrics overall and within prespecified periods. RESULTS Participants (25% male) had mean±SD age 44.7±14.2 years, T1D duration 30.2±11.1 years, A1C 7.2±0.8%, and insulin usage 0.53±0.21 U/kg/day. Percent TIR 70-180 mg/dL (mean±SD) was 81.2±8.4 overall, 85.2±8.1 outside of challenge periods, 97.3±5.3 during the nocturnal periods, and 74.5±16.2 for the postprandial periods. During challenge periods, percent TIR for the over-bolus challenge was 65.4±29.2 and for the delayed bolus challenge was 57.1±25.1. No adverse events, serious adverse events or unanticipated adverse device events occurred while participants were using the HCL system. CONCLUSION In participants with T1D, Lilly AID system demonstrated expected algorithm performance and safety with satisfactory glycemic outcomes overall and in response to simulated diabetes management challenges. Additional studies in less supervised conditions and with broader patient populations are warranted.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date